0451.100MRL vs 0451.062MRL

0451.100MRLと0451.062MRLの詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The 0451.062MRL is a lower-current-rated fuse of the same series and physical format as the 0451.100MRL, making it a viable functional replacement candidate only where the reduced current rating is acceptable. Both share identical voltage rating, package type, and operating temperature range, but the difference in current rating must be validated against the actual circuit load before substitution.

Current Rating Validation required
Voltage Rating High match
Package Type High match
Operating Temperature High match

Parts at a glance

Part A

0451.100MRL

リテルヒューズ社

Lifecycle
Active
Stock
4267 個数
Package
2-SMD, Square End Block
Series
ヒューズ
Part B

0451.062MRL

リテルヒューズ社

Lifecycle
Active
Stock
4270 個数
Package
2-SMD, Square End Block
Series
ヒューズ

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter 0451.100MRL 0451.062MRL Why it matters
Current Rating 100 mA 62 mA Determines the maximum continuous current the fuse can carry without opening; a lower-rated fuse will open at lower fault currents.
Voltage Rating 125 V 125 V Specifies the maximum voltage the fuse can safely interrupt; must meet or exceed the circuit voltage.
Breaking Capacity 50 A 50 A Indicates the maximum fault current the fuse can safely interrupt without damage or hazard.
Melting I²t 0.0025 A²s 0.001 A²s Represents the energy required to melt the fuse element; affects opening speed under fault conditions.
Nominal Cold Resistance 3.5 Ohms 7.5 Ohms Higher resistance causes greater voltage drop and power loss in normal operation.
Voltage Drop at Rated Current 0.35 V 0.47 V Affects the voltage available to the load and overall circuit efficiency.
Fuse Type Slow-Blow (Time-Lag) Slow-Blow (Time-Lag) Determines tolerance to inrush currents; slow-blow fuses withstand temporary surges without opening.
Package Size 5 mm x 20 mm 5 mm x 20 mm Physical dimensions must match the fuse holder or clip for proper fit and contact.
Operating Temperature Range -55°C to +125°C -55°C to +125°C Ensures reliable operation and correct breaking characteristics across the application's temperature range.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification 0451.100MRL 0451.062MRL
Series NANO²® 451 NANO²® 451
Part Status Active Active
Mounting Type Surface Mount Surface Mount
Fuse Type Board Mount (Cartridge Style Excluded) Board Mount (Cartridge Style Excluded)
Current Rating (Amps) 100 mA 62 mA
Voltage Rating - AC 125 V 125 V
Voltage Rating - DC 125 V 125 V
Response Time Fast Blow Fast Blow
Breaking Capacity @ Rated Voltage 50A 50A
Melting I²t 0.00138 0.00019
Approval Agency CSA, UL CSA, UL
Operating Temperature -55°C ~ 125°C -55°C ~ 125°C

Frequently asked questions

What are the 0451.100MRL and 0451.062MRL fuses?

The 0451.100MRL and 0451.062MRL are surface-mount, very fast-acting ceramic body fuses from Littelfuse's 451 series. The 0451.100MRL is rated 100 mA and the 0451.062MRL is rated 62 mA, both with a 125 V AC/VDC voltage rating and a 6.1 mm x 2.69 mm footprint.

What is the main difference between the 0451.100MRL and 0451.062MRL?

The primary difference is the current rating: the 0451.100MRL has a 100 mA rating, while the 0451.062MRL has a 62 mA rating. Both share the same 451 series platform, 125 V rating, fast-acting characteristic, and surface-mount ceramic package.

Are the 0451.100MRL and 0451.062MRL interchangeable in a circuit?

No, they are not directly interchangeable because their current ratings differ. Substituting a 100 mA fuse for a 62 mA fuse (or vice versa) changes the overcurrent trip point and can compromise circuit protection. Replacement must follow the original design's specified current rating and the manufacturer's datasheet.

What is the voltage rating of the 0451.100MRL and 0451.062MRL?

Both the 0451.100MRL and 0451.062MRL are rated for 125 V AC and 125 V DC, as specified in the Littelfuse 451 series datasheet.

What is the breaking capacity of the 0451.100MRL and 0451.062MRL?

Both fuses in the Littelfuse 451 series have a breaking capacity of 50 A at 125 V AC and 300 A at 125 V DC, per the manufacturer's datasheet.

What are the physical dimensions and mounting type of these fuses?

The 0451.100MRL and 0451.062MRL are surface-mount fuses in a ceramic body with a footprint of approximately 6.1 mm x 2.69 mm. They are supplied on tape and reel for automated PCB assembly.

What is the operating temperature range for the 0451.100MRL and 0451.062MRL?

Both fuses are rated for operation from -55 °C to +125 °C, according to the Littelfuse 451 series datasheet.

Do the 0451.100MRL and 0451.062MRL carry any agency approvals?

Yes, the Littelfuse 451 series fuses are recognized under UL/CSA and meet relevant industry standards as stated in the manufacturer's datasheet. Designers should confirm the specific approval markings on the current datasheet for the exact part number.