0451003.MRL
リテルヒューズ社
- Lifecycle
- Active
- Stock
- 7735 個数
- Series
- ヒューズ
0451003.MRLと0451002.MRLの詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。
Replacement verdict
The 0451002.MRL and 0451003.MRL are both surface-mount slow-blow ceramic fuses from the same Littelfuse 451 series, sharing identical package, voltage rating, and operating temperature range. The only meaningful difference is the current rating, making the 0451003.MRL a viable higher-current alternative where the circuit design permits.
リテルヒューズ社
リテルヒューズ社
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | 0451002.MRL | 0451003.MRL | Why it matters |
|---|---|---|---|
| Current Rating | 2 A | 3 A | Determines the maximum continuous current the fuse can carry without opening; a direct functional difference affecting circuit protection level. |
| Melting I²t | 1.6 A²s | 4.4 A²s | Indicates the energy required to open the fuse; affects response time under fault currents and coordination with downstream components. |
| Nominal Cold Resistance | 0.0455 Ohm | 0.0285 Ohm | Lower resistance reduces voltage drop and power loss; impacts circuit efficiency and thermal behavior. |
| Voltage Drop at Rated Current | 0.091 V | 0.0855 V | Affects the voltage available to the load and overall circuit performance; a key indicator of insertion loss. |
| Voltage Rating | 125 V AC / 125 V DC | 125 V AC / 125 V DC | Defines the maximum voltage the fuse can safely interrupt; must meet or exceed the application voltage. |
| Interrupting Rating | 50 A at 125 V AC / 300 A at 125 V DC | 50 A at 125 V AC / 300 A at 125 V DC | Specifies the maximum fault current the fuse can safely break without damage or hazard. |
| Fuse Type | Fast-Acting | Fast-Acting | Determines response speed to overcurrent events; fast-acting is suitable for sensitive electronics protection. |
| Package / Size | 1206 (3216 Metric) | 1206 (3216 Metric) | Ensures physical compatibility with the PCB footprint and assembly process. |
| Operating Temperature Range | -55°C to +125°C | -55°C to +125°C | Defines the environmental conditions under which the fuse maintains reliable performance. |
| Approvals / Certifications | UL Recognized, CSA Certified | UL Recognized, CSA Certified | Indicates compliance with safety standards required for end-product certification. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | 0451003.MRL | 0451002.MRL |
|---|---|---|
| Series | NANO²® 451 | NANO²® 451 |
| Part Status | Active | Active |
| Mounting Type | Surface Mount | Surface Mount |
| Fuse Type | Board Mount (Cartridge Style Excluded) | Board Mount (Cartridge Style Excluded) |
| Current Rating (Amps) | 3 A | 2 A |
| Voltage Rating - AC | 125 V | 125 V |
| Voltage Rating - DC | 125 V | 125 V |
| Response Time | Fast Blow | Fast Blow |
| Breaking Capacity @ Rated Voltage | 50A | 50A |
| Melting I²t | 1.65 | 0.53 |
| Approval Agency | CSA, PSE, UL | CSA, PSE, UL |
| Operating Temperature | -55°C ~ 125°C | -55°C ~ 125°C |
| Size / Dimension | 0.240" L x 0.106" W x 0.106" H (6.10mm x 2.69mm x 2.69mm) | - |
| Packaging | Cut Tape (CT), Tape & Reel (TR) | - |
The 0451002.MRL and 0451003.MRL are Littelfuse Nano2 SMF series surface-mount fuses. The 0451002.MRL is rated 2 A and the 0451003.MRL is rated 3 A, both in a 2410 (6125 metric) package with a 125 V AC / 125 V DC voltage rating and a 50 A interrupting rating.
The primary difference is the current rating: the 0451002.MRL is rated for 2 A and the 0451003.MRL is rated for 3 A. Both share the same Nano2 SMF fuse family, 2410 surface-mount package, 125 V AC / 125 V DC voltage rating, and 50 A interrupting rating.
No. Although they share the same package and voltage rating, their current ratings differ (2 A vs. 3 A). Substitution must be evaluated against the circuit's normal operating current, inrush profile, and required overcurrent protection level using the Littelfuse datasheet.
Both the 0451002.MRL and 0451003.MRL are rated for 125 V AC and 125 V DC, as specified in the Littelfuse Nano2 SMF series datasheet.
Both fuses have an interrupting rating of 50 A at 125 V AC and 50 A at 125 V DC, per the Littelfuse Nano2 SMF series specifications.
Both the 0451002.MRL and 0451003.MRL use the Littelfuse Nano2 SMF surface-mount package in a 2410 (6125 metric) footprint, suitable for automated PCB assembly.
They share the same interrupting rating of 50 A at 125 V AC / 125 V DC and belong to the same Littelfuse Nano2 SMF series, so their time-current curve family is the same. However, the 2 A and 3 A ratings correspond to different points on that curve, so actual clearing times at a given fault current differ.
Selection depends on the circuit's steady-state current and required protection threshold. The 0451002.MRL (2 A) is used where normal operating current is below 2 A, while the 0451003.MRL (3 A) is used where normal operating current is below 3 A. Both are applicable in 125 V AC / 125 V DC circuits requiring a 50 A interrupting rating, subject to Littelfuse derating and application guidelines.