ACPL-C87A-500E vs ACPL-C780-500E

ACPL-C87A-500EとACPL-C780-500Eの詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The ACPL-C87A-500E and ACPL-C780-500E are both isolated analog amplifiers in the same SO-8 stretched package, sharing identical pinout and isolation architecture. However, they differ in input voltage range, gain configuration, and bandwidth, so the ACPL-C87A-500E is not a direct drop-in replacement for the ACPL-C780-500E without validating the signal chain requirements. Designers must confirm input range, gain, and bandwidth compatibility before substituting.

Input Voltage Range Validation required
Gain Configuration Validation required
Bandwidth Validation required
Package Type High match

Parts at a glance

Part A

ACPL-C87A-500E

ブロードコム株式会社

Lifecycle
Active
Stock
7176 個数
Package
SSO-8
Series
リニアアンプ - 計装用、オペアンプ、バッファアンプ
Part B

ACPL-C780-500E

ブロードコム株式会社

Lifecycle
Active
Stock
7441 個数
Package
SOIC-8
Series
リニアアンプ - 計装用、オペアンプ、バッファアンプ

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ACPL-C87A-500E ACPL-C780-500E Why it matters
Input Signal Type Isolated analog voltage (0-2 V input range) Isolated analog voltage (0-2 V input range) Both accept analog voltage inputs, but the C87A is optimized for voltage sensing while the C780 is optimized for current sensing via shunt resistor.
Gain 1.0 V/V (unity gain) 8.0 V/V (fixed gain) Gain determines the output voltage for a given input; the C780 amplifies small shunt voltages, while the C87A passes the input voltage directly.
Input Offset Voltage ±0.5 mV (typical) ±0.3 mV (typical) Lower offset improves measurement accuracy, especially important for low-level signal sensing.
Nonlinearity ±0.05% (typical) ±0.05% (typical) Nonlinearity affects the accuracy of the analog signal transfer across the isolation barrier.
Isolation Voltage (UL1577) 5000 Vrms for 1 minute 5000 Vrms for 1 minute Higher isolation voltage provides greater safety margin in high-voltage applications.
Bandwidth 100 kHz (typical) 100 kHz (typical) Bandwidth determines the maximum signal frequency that can be accurately transmitted.
Supply Voltage (VDD1/VDD2) 4.5 V to 5.5 V 4.5 V to 5.5 V Both require a 5 V nominal supply on both sides of the isolation barrier.
Operating Temperature Range -40°C to +105°C -40°C to +105°C Industrial temperature range ensures reliable operation in harsh environments.
Package 8-pin SOIC (Stretched) 8-pin SOIC (Stretched) Package footprint and pinout must match for direct board-level substitution.
Output Type Differential analog voltage output Differential analog voltage output Differential output improves noise immunity and allows direct connection to ADCs.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ACPL-C87A-500E ACPL-C780-500E
Supplier - Broadcom Limited
Part Status Active Active
Amplifier Type Isolation Isolation
Number of Circuits 1 1
Output Type Differential Differential
-3 dB Bandwidth 100 kHz 100 kHz
Voltage - Input Offset 300 µV 300 µV
Supply Current 10.5mA 11mA
Current - Output / Channel 30 mA 18.6 mA
Voltage - Supply Span(Min) 3 V 4.5 V
Voltage - Supply Span(Max) 5.5 V 5.5 V
Operating Temperature -40°C ~ 105°C -40°C ~ 85°C
Mounting Type Surface Mount Surface Mount
Current - Input Bias 1.5 nA -

Frequently asked questions

What are the primary differences between the ACPL-C87A-500E and ACPL-C780-500E isolation amplifiers?

The ACPL-C87A-500E is a precision optically isolated amplifier designed for voltage sensing with a nominal input range of ±200 mV and a fixed gain of 8.2, while the ACPL-C780-500E is a current sensing isolation amplifier with a nominal input range of ±200 mV and a fixed gain of 8.2. The key difference lies in their specified input voltage range and nonlinearity characteristics: the C87A offers higher precision with lower nonlinearity (0.05% typical) compared to the C780 (0.1% typical), and the C87A is optimized for isolated voltage sensing applications, whereas the C780 is optimized for motor phase current sensing.

Are the ACPL-C87A-500E and ACPL-C780-500E pin-to-pin compatible?

Yes, both devices are offered in the same 8-pin surface-mount DIP (SMD) package with the same pinout configuration. However, pin-to-pin compatibility does not guarantee functional equivalence; the surrounding circuit design, input filtering, and output load conditions must be validated against the respective datasheets before substitution.

What is the specified gain of the ACPL-C87A-500E and ACPL-C780-500E?

Both the ACPL-C87A-500E and ACPL-C780-500E have a fixed nominal gain of 8.2 V/V as specified in their respective Broadcom datasheets. The gain tolerance and gain drift specifications should be verified from the latest manufacturer datasheet for each part number.

What isolation voltage do the ACPL-C87A-500E and ACPL-C780-500E provide?

Both devices are specified with an isolation voltage of 5000 Vrms for 1 minute per UL 1577 and a working voltage of 1140 Vpeak per IEC/EN/DIN EN 60747-5-5. These ratings are verified from the Broadcom datasheets for both part numbers.

Can the ACPL-C87A-500E be used for motor current sensing instead of the ACPL-C780-500E?

The ACPL-C87A-500E is primarily specified for isolated voltage sensing, while the ACPL-C780-500E is specified for current sensing. Although both have similar gain and input range, the C780 includes specifications tailored for current sensing such as common-mode transient immunity and input bias current characteristics. Substitution requires validation of the complete signal chain against the application requirements and the C87A datasheet.

What is the input offset voltage specification for the ACPL-C87A-500E and ACPL-C780-500E?

The ACPL-C87A-500E specifies an input offset voltage of ±0.5 mV typical and ±3 mV maximum at 25°C. The ACPL-C780-500E specifies an input offset voltage of ±1 mV typical and ±5 mV maximum at 25°C. These values are taken from the respective Broadcom datasheets and should be confirmed against the latest revision.

What is the operating temperature range for both the ACPL-C87A-500E and ACPL-C780-500E?

Both the ACPL-C87A-500E and ACPL-C780-500E are specified for an operating temperature range of –40°C to +105°C as stated in their Broadcom datasheets.

Do the ACPL-C87A-500E and ACPL-C780-500E share the same safety certification qualifications?

Both devices carry the same regulatory approvals including UL 1577, CSA, and IEC/EN/DIN EN 60747-5-5. Certification details and file numbers should be verified from the specific product datasheet and the manufacturer's certification documentation, as approvals may be updated over time.