ACS722LLCTR-10AU-T
アレグロ・マイクロシステムズ
- Lifecycle
- Active
- Stock
- 4978 個数
- Package
- SOIC-N-8
- Series
- 電流センサー
ACS722LLCTR-10AU-TとACS723LLCTR-05AB-Tの詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。
Replacement verdict
The ACS722LLCTR-10AU-T is not a direct drop-in replacement for the ACS723LLCTR-05AB-T due to differences in current sensing range, output type, and package construction. However, both devices share the same Allegro current sensor family architecture, bidirectional sensing capability, and similar supply voltage requirements, making the ACS722 a viable functional substitute in applications where the higher current range is acceptable and the unidirectional output configuration can be accommodated through circuit redesign.
アレグロ・マイクロシステムズ
アレグロ・マイクロシステムズ
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ACS723LLCTR-05AB-T | ACS722LLCTR-10AU-T | Why it matters |
|---|---|---|---|
| Current Sensing Range | ±5 A | ±10 A | Defines the maximum measurable current; a smaller range offers finer resolution for low-current loads, while a larger range supports higher-power applications. |
| Sensitivity | 400 mV/A | 132 mV/A | Higher sensitivity provides greater output voltage per amp, improving accuracy and noise immunity for low-current measurements. |
| Supply Voltage | 4.5 V to 5.5 V | 3.0 V to 3.6 V | Determines compatibility with the system power rail; mismatched supply voltages require level shifting or a different regulator. |
| Output Type | Analog, ratiometric | Analog, ratiometric | Ratiometric analog output scales with supply voltage, so the ADC reference must match the sensor supply for accurate readings. |
| Isolation Voltage | 2.1 kVrms | 3.0 kVrms | Higher isolation rating provides greater safety margin when sensing currents referenced to hazardous or high-voltage potentials. |
| Bandwidth | 80 kHz | 80 kHz | Sets the maximum signal frequency the sensor can track; adequate bandwidth is needed for fast current transients and PWM loads. |
| Package | 8-lead SOIC | 8-lead SOIC | Footprint and pinout must match for a drop-in replacement on an existing PCB layout. |
| Operating Temperature Range | -40 °C to 150 °C | -40 °C to 150 °C | Ensures the sensor meets accuracy and reliability specifications across the application's ambient and self-heating conditions. |
| Accuracy | ±3% typical | ±3% typical | Total error over temperature and current affects measurement precision and system calibration requirements. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ACS722LLCTR-10AU-T | ACS723LLCTR-05AB-T |
|---|---|---|
| Part Status | Active | Active |
| For Measuring | DC | AC/DC |
| Sensor Type | Hall Effect, Open Loop | Hall Effect, Open Loop |
| Current - Sensing | 10A | 5A |
| Number of Channels | 1 | 1 |
| Output | Ratiometric, Voltage | Ratiometric, Voltage |
| Sensitivity | 264mV/A | 400mV/A |
| Frequency | DC ~ 80kHz | DC ~ 80kHz |
| Linearity | ±1% | ±1% |
| Accuracy | ±3% | ±3% |
| Voltage - Supply | 3V ~ 3.6V | 5V |
| Response Time | 5µs | 5µs |
| Current - Supply (Max) | 12mA | 14mA |
| Operating Temperature | -40°C ~ 150°C | -40°C ~ 150°C |
| Polarization | Unidirectional | Bidirectional |
| Mounting Type | Surface Mount | Surface Mount |
The ACS723LLCTR-05AB-T is a galvanically isolated current sensor with a 5 A bidirectional measurement range and an analog output, while the ACS722LLCTR-10AU-T is a galvanically isolated current sensor with a 10 A unidirectional measurement range and an analog output. The ACS723 device is specified for bidirectional current sensing, whereas the ACS722 device is specified for unidirectional current sensing.
Both devices are offered in the same SOIC-8 package footprint, but pin-to-pin compatibility cannot be assumed solely from the package. The ACS723LLCTR-05AB-T and ACS722LLCTR-10AU-T have different measurement ranges and directionality, so the surrounding circuit and firmware must be validated against the respective datasheets before any substitution.
The ACS723LLCTR-05AB-T has a specified current measurement range of ±5 A (bidirectional). The ACS722LLCTR-10AU-T has a specified current measurement range of 0 A to 10 A (unidirectional).
Both the ACS723LLCTR-05AB-T and the ACS722LLCTR-10AU-T are designed for a single 3.3 V supply voltage, as specified in their respective Allegro MicroSystems datasheets.
Both devices provide an analog voltage output proportional to the sensed current. The ACS723LLCTR-05AB-T output is centered at mid-supply for bidirectional sensing, while the ACS722LLCTR-10AU-T output is referenced for unidirectional sensing.
Both the ACS723LLCTR-05AB-T and the ACS722LLCTR-10AU-T are galvanically isolated current sensors. The specific isolation voltage rating should be taken from the official Allegro MicroSystems datasheet for each part number, as it is a critical safety parameter.
Direct replacement is not recommended without a full design review. The ACS723LLCTR-05AB-T is bidirectional and rated for ±5 A, while the ACS722LLCTR-10AU-T is unidirectional and rated for 10 A. The different range and directionality affect sensitivity, output voltage swing, and firmware scaling, so the target application must be revalidated against the ACS723LLCTR-05AB-T datasheet.
Both devices are used for current sensing in industrial, automotive, and consumer applications. The ACS723LLCTR-05AB-T is suited for bidirectional current monitoring such as motor control and power management, while the ACS722LLCTR-10AU-T is suited for unidirectional current monitoring such as load detection and power supply monitoring.