AD7401YRWZ vs AD7401AYRWZ

AD7401YRWZとAD7401AYRWZの詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The AD7401AYRWZ and AD7401YRWZ are functionally equivalent isolated sigma-delta modulators sharing the same core architecture, package footprint, and electrical specifications; the AY suffix denotes an automotive-qualified grade while the Y grade is the standard industrial version, so the AY part can serve as a higher-reliability substitute for the Y part in most designs, subject to confirming the target application's qualification and temperature requirements.

Package Type High match
Output Type High match
Operating Temperature Validation required
Qualification Grade Validation required

Parts at a glance

Part A

AD7401YRWZ

テキサス・インスツルメンツ

Lifecycle
Active
Stock
5354 個数
Package
SOIC-16
Series
データ取得 - ADC/DAC - 特殊用途向け
Part B

AD7401AYRWZ

テキサス・インスツルメンツ

Lifecycle
Active
Stock
5262 個数
Package
SOIC-16
Series
データ取得 - ADC/DAC - 特殊用途向け

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AD7401AYRWZ AD7401YRWZ Why it matters
Manufacturer Part Number AD7401AYRWZ AD7401YRWZ The "A" suffix denotes an automotive-qualified variant, while the base part is the standard industrial version; this affects qualification and sourcing.
Automotive Qualification AEC-Q100 qualified Not AEC-Q100 qualified (industrial grade) Automotive qualification determines suitability for automotive applications requiring AEC-Q100 compliance and stricter reliability screening.
Operating Temperature Range -40°C to +125°C -40°C to +105°C The wider temperature range of the automotive version allows operation in harsher environments and affects thermal design margins.
Resolution 16-bit 16-bit Resolution determines the measurement precision of the isolated sigma-delta modulator; both parts provide the same 16-bit output.
Isolation Voltage (VISO) 5 kV rms 5 kV rms Isolation rating is critical for safety and noise immunity in high-voltage measurement applications; both parts share the same rating.
Supply Voltage 5 V (VDD1 and VDD2) 5 V (VDD1 and VDD2) Supply voltage compatibility ensures the part can be dropped into the same power rail design without changes.
Package 16-lead SOIC (RW-16) 16-lead SOIC (RW-16) Package and footprint compatibility allows direct board-level substitution without layout changes.
Output Interface Serial (sigma-delta bitstream) Serial (sigma-delta bitstream) The output format must match the digital filter/controller interface; both parts use the same sigma-delta bitstream output.
Data Rate Up to 20 MHz clock Up to 20 MHz clock Maximum clock rate determines achievable sampling bandwidth and is identical for both variants.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AD7401YRWZ AD7401AYRWZ
Series iCoupler® iCoupler®
Part Status Active Active
Type Isolated Module Isolated Module
Number of Channels 1 1
Resolution(Bits) 16 b 16 b
Data Interface Serial Serial
Voltage Supply Source Dual Supply Dual Supply
Voltage - Supply 3V ~ 5.5V, 5V -
Operating Temperature -40°C ~ 105°C -40°C ~ 125°C
Mounting Type Surface Mount Surface Mount

Frequently asked questions

What are the key differences between the AD7401AYRWZ and AD7401YRWZ?

Both are isolated sigma-delta modulators from Analog Devices in a 16-lead SOIC (RW-16) package. The primary difference is the temperature grade: the AD7401AYRWZ is specified for the automotive/industrial temperature range of −40°C to +125°C, while the AD7401YRWZ is specified for −40°C to +105°C. The "A" suffix denotes the extended temperature grade.

Are the AD7401AYRWZ and AD7401YRWZ functionally and pin-compatible?

Yes. Both devices share the same functional block diagram, pinout, and 16-lead SOIC (RW-16) package. They are functionally and pin-compatible; the difference is limited to the rated operating temperature range and the corresponding grade designation.

What is the maximum operating temperature of each device?

The AD7401AYRWZ is rated for operation from −40°C to +125°C. The AD7401YRWZ is rated for operation from −40°C to +105°C. Designs requiring operation above +105°C should use the AD7401AYRWZ.

What are the core specifications shared by both devices?

Both are second-order sigma-delta modulators with an on-chip digital isolator, a 16-bit output, and a typical throughput of 20 MHz. They operate from a 5 V supply on the analog side and a 3 V to 5.5 V supply on the digital side, and provide galvanic isolation rated at 5 kV rms per UL 1577. They are intended for current sensing in motor control and power inverter applications.

Can the AD7401YRWZ be used as a drop-in replacement for the AD7401AYRWZ?

Only if the application's maximum ambient temperature does not exceed +105°C. Because the AD7401YRWZ has a lower rated maximum temperature, substituting it for the AD7401AYRWZ in a design that operates above +105°C would exceed the device's specified operating range and is not recommended.

Do both parts carry the same isolation and safety certifications?

Both devices use the same isolated modulator architecture and are rated for 5 kV rms isolation per UL 1577. However, designers should confirm the specific certification file numbers and qualification status for each orderable part number against the current Analog Devices datasheet and safety certificate before finalizing a design.

Which part should be selected for automotive or high-temperature industrial designs?

The AD7401AYRWZ should be selected for applications requiring operation up to +125°C, including many automotive and high-temperature industrial motor-control designs. The AD7401YRWZ is suitable for applications where the ambient temperature stays within −40°C to +105°C.