AD7616BSTZ
テキサス・インスツルメンツ
- Lifecycle
- Active
- Stock
- 1872 個数
- Series
- データ取得 - アナログ/デジタルコンバータ (ADC)
AD7616BSTZとAD7610BSTZの詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。
Replacement verdict
The AD7616BSTZ is a higher-channel-count successor to the AD7610BSTZ, offering 16 simultaneous-sampling channels versus a single channel while preserving the same 16-bit SAR architecture, ±10 V bipolar input range, and 5 V analog supply. Both devices share the LQFP-64 package footprint and industrial temperature range, making the AD7616BSTZ a viable functional upgrade candidate where additional channel density is required, provided the system timing, digital interface configuration, and power budget are revalidated against the new channel count.
テキサス・インスツルメンツ
テキサス・インスツルメンツ
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | AD7610BSTZ | AD7616BSTZ | Why it matters |
|---|---|---|---|
| Resolution | 16 bits | 16 bits | Both are 16-bit ADCs, so nominal resolution is equivalent and neither offers a resolution advantage for substitutability. |
| Number of ADC Channels | 1 (single channel) | 16 (dual simultaneous-sampling, 8+8) | Channel count is the most critical difference; the AD7616 can digitize many inputs simultaneously while the AD7610 handles only one, so they are not drop-in substitutes in multi-channel systems. |
| Sampling Rate | 250 kSPS | 1 MSPS (500 kSPS per channel) | The AD7616 offers higher throughput, which affects achievable signal bandwidth and system timing budgets. |
| Input Configuration | Single-ended (bipolar/unipolar, software-selectable) | Differential (true differential inputs) | Differential inputs improve noise immunity and common-mode rejection, but require different front-end signal conditioning than single-ended inputs. |
| Interface Type | Parallel (byte/word) and serial SPI-compatible | Parallel (byte/word) and serial SPI-compatible | Both support parallel and serial interfaces, easing digital-side integration, though pinouts and timing differ. |
| Analog Supply Voltage | 5 V analog supply | 5 V analog supply | Matching analog supply rails simplifies power-tree reuse when evaluating substitution. |
| Package | 48-lead LQFP | 64-lead LQFP | Different package footprints and pin counts mean the boards are not layout-compatible; a redesign is required to swap parts. |
| Internal Reference | On-chip reference (with internal buffer) | On-chip reference (with internal buffer) | Both integrate a reference, reducing external component count, but reference accuracy and drift specifications should be checked for precision-critical designs. |
| Operating Temperature Range | -40 °C to +85 °C | -40 °C to +85 °C | Identical industrial temperature ratings mean environmental suitability is equivalent for both parts. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | AD7616BSTZ | AD7610BSTZ |
|---|---|---|
| Part Status | Active | Active |
| Base Product Number | AD7616 | - |
| Number of Bits | 16 | 16 |
| Sampling Rate (Per Second) | 1M | - |
| Number of Inputs | 16 | 1 |
| Input Type | Single Ended | Differential |
| Data Interface | DSP, MICROWIRE™, Parallel, QSPI™, Serial, SPI™ | SPI, Parallel, DSP |
| Configuration | MUX-ADC | S/H-ADC |
| Number of A / D Converters | 2 | - |
| Architecture | SAR | SAR |
| Reference Type | External, Internal | External, Internal |
| Voltage - Supply, Analog | 4.75V ~ 5.25V | 5V |
| Voltage - Supply, Digital | 2.3V ~ 3.6V | 5V |
| Features | Simultaneous Sampling | True Bipolar |
| Operating Temperature | -40°C ~ 125°C | -40°C ~ 85°C |
| Mounting Type | Surface Mount | - |
| Packaging | Tray | - |
| Series | - | iCMOS®, PulSAR® |
| Sampling Rate(Per Second) | - | 250k |
| Ratio - S / H: ADC | - | 1:1 |
| Number of A/D Converters | - | 1 |
The AD7610BSTZ is a single-channel, 16-bit successive-approximation register (SAR) analog-to-digital converter with a maximum throughput of 250 kSPS. The AD7616BSTZ is a dual-channel, 16-bit SAR ADC that provides two simultaneous-sampling channels with a maximum throughput of 1 MSPS per channel. The AD7616BSTZ integrates two ADCs in one package, while the AD7610BSTZ contains one ADC.
No. The AD7610BSTZ is offered in a 48-lead LQFP package, while the AD7616BSTZ is offered in a 64-lead LQFP package. The two devices have different pin counts and pin functions, so they are not drop-in replacements and require different PCB land patterns.
The AD7610BSTZ provides a single analog input channel that can be configured for either single-ended or differential input ranges. The AD7616BSTZ provides two independent analog input channels, each supporting single-ended or differential configurations, enabling simultaneous sampling of two signals.
The AD7610BSTZ has a maximum throughput rate of 250 kSPS. The AD7616BSTZ has a maximum throughput rate of 1 MSPS per channel, with both channels capable of simultaneous conversion.
Both devices provide a parallel digital interface for output data. The AD7610BSTZ offers a 16-bit parallel interface, while the AD7616BSTZ provides a 16-bit parallel interface per channel with additional configuration and control pins to manage dual-channel operation. The interface timing and control signals differ between the two devices and must be reviewed in the respective datasheets.
Not directly. The AD7616BSTZ has a different package (64-lead LQFP versus 48-lead LQFP), a different pinout, a higher maximum throughput (1 MSPS versus 250 kSPS), and dual-channel architecture. A redesign of the PCB layout, interface logic, and system timing would be required, and all differences must be validated against the manufacturer datasheets before substitution.
The AD7610BSTZ is typically used in single-channel precision data acquisition systems, industrial instrumentation, and medical instrumentation where a 250 kSPS, 16-bit SAR ADC is sufficient. The AD7616BSTZ is suited for multi-channel simultaneous-sampling applications such as power quality monitoring, motor control, and protective relays, where two channels must be sampled at the same instant at up to 1 MSPS per channel.