AD7709ARUZ vs AD7707BRU

AD7709ARUZとAD7707BRUの詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The AD7709ARUZ and AD7707BRU are both 16-bit sigma-delta ADCs from Analog Devices, but they differ fundamentally in input channel configuration, package footprint, and supply voltage range, so neither part can directly substitute for the other without a full schematic and layout redesign.

Different input channel configuration Different package footprint Different supply voltage range Different interface and feature set

Parts at a glance

Part A

AD7709ARUZ

テキサス・インスツルメンツ

Lifecycle
Active
Stock
1974 個数
Package
TSSOP-24
Series
データ取得 - アナログ/デジタルコンバータ (ADC)
Part B

AD7707BRU

テキサス・インスツルメンツ

Lifecycle
Active
Stock
8840 個数
Package
TSSOP-20
Series
データ取得 - アナログ/デジタルコンバータ (ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AD7709ARUZ AD7707BRU Why it matters
Resolution (bits) 16 16 Both are 16-bit sigma-delta ADCs, so resolution is equivalent for precision measurement applications.
Number of input channels 4 differential / 8 single-ended (with PGA) 3 differential / 5 single-ended Channel count determines how many sensor signals can be multiplexed into one converter; the AD7709 offers more inputs.
Programmable gain amplifier (PGA) range 1 to 128 1 to 128 PGA gain range affects the ability to interface small-amplitude signals directly without external amplification.
Output data rate Up to 105 Hz (19.79 Hz to 105 Hz) Up to 500 Hz (programmable) Higher output data rates support faster measurement loops; the AD7707 can update faster than the AD7709.
Supply voltage 2.7 V to 5.25 V 2.7 V to 3.3 V (DVDD), 4.75 V to 5.25 V (AVDD) Supply requirements affect compatibility with the system power rail; the AD7707 needs a separate 5 V analog supply.
Interface type SPI / 3-wire serial SPI / 3-wire serial Both use a compatible serial interface, simplifying drop-in replacement at the digital interface level.
Package 24-lead TSSOP 20-lead TSSOP Different package pin counts and footprints mean the parts are not physically drop-in compatible on the same PCB.
Operating temperature range -40 °C to +85 °C -40 °C to +85 °C Identical temperature ratings mean both suit the same industrial environmental conditions.
On-chip features PGA, current sources, reference detect, burnout current PGA, reference detect, burnout current Integrated current sources in the AD7709 simplify RTD/sensor excitation, which the AD7707 lacks.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AD7709ARUZ AD7707BRU
Supplier - Analog Devices Inc.,Rochester Electronics, LLC
Part Status Active Obsolete
Number of Bits 16 16
Sampling Rate(Per Second) 105 500
Number of Inputs 2, 4 1, 2
Input Type Differential, Pseudo-Differential Pseudo-Differential, Single Ended
Data Interface SPI, DSP SPI, DSP
Configuration MUX-PGA-ADC MUX-PGA-ADC
Number of A/D Converters 1 1
Architecture Sigma-Delta Sigma-Delta
Reference Type External External
Voltage - Supply, Analog 2.7V ~ 3.3V, 5V 2.7V ~ 3.3V, 5V
Voltage - Supply, Digital 2.7V ~ 3.3V, 5V 2.7V ~ 3.3V, 5V
Features PGA PGA
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C

Frequently asked questions

What are the key differences between the AD7709ARUZ and the AD7707BRU?

The AD7709ARUZ is a 16-bit sigma-delta ADC with a 4-channel input multiplexer, on-chip programmable gain amplifier, and current sources, housed in a 24-lead TSSOP. The AD7707BRU is a 16-bit sigma-delta ADC with a 3-channel input multiplexer (one high-level and two low-level inputs) and is specified for higher performance grades, also in a 24-lead TSSOP. The AD7709 is optimized for low-level signal conditioning with integrated excitation current sources, while the AD7707 is designed for mixed high-level and low-level input applications.

Are the AD7709ARUZ and AD7707BRU pin-compatible?

No. Although both devices are offered in a 24-lead TSSOP package, their pin functions differ. The AD7709ARUZ includes dedicated pins for its current sources and 4-channel multiplexer, while the AD7707BRU has a different multiplexer configuration with one high-level input channel. A direct drop-in replacement is not possible without verifying pin assignments against the respective datasheets.

What is the resolution and architecture of both ADCs?

Both the AD7709ARUZ and AD7707BRU are 16-bit sigma-delta analog-to-digital converters. They use a sigma-delta modulation architecture with on-chip digital filtering, providing high resolution for low-frequency signal measurement applications.

How do the input channel configurations differ between the two parts?

The AD7709ARUZ provides a 4-channel input multiplexer with fully differential or single-ended input options and an on-chip programmable gain amplifier. The AD7707BRU provides a 3-channel input multiplexer consisting of one high-level input channel and two low-level input channels, allowing direct connection of higher-voltage signals without external attenuation.

Do both devices include on-chip current sources for sensor excitation?

The AD7709ARUZ includes on-chip programmable current sources intended for direct excitation of resistive sensors such as RTDs and thermistors. The AD7707BRU does not include these integrated excitation current sources; external excitation circuitry would be required for sensor applications.

What are the supply voltage and interface characteristics of these ADCs?

Both devices operate from a single supply and include a serial interface for communication with a microcontroller or DSP. The AD7709ARUZ and AD7707BRU are specified for operation over the industrial temperature range. Detailed supply voltage ranges, reference requirements, and interface timing should be confirmed in the respective manufacturer datasheets before design implementation.

Which device is better suited for RTD or thermistor measurement?

The AD7709ARUZ is generally better suited for RTD and thermistor measurement because it integrates programmable excitation current sources and a 4-channel multiplexer, reducing external component count. The AD7707BRU lacks integrated current sources, so external excitation circuitry would be needed for such sensor applications.

Can the AD7707BRU replace the AD7709ARUZ in an existing design?

Not directly. The two devices differ in multiplexer channel configuration, integrated current sources, and pin functions. A replacement would require schematic and layout changes, and the system performance must be revalidated against the target specifications using the AD7707BRU datasheet.