AD7730BRUZ
テキサス・インスツルメンツ
- Lifecycle
- Active
- Stock
- 7421 個数
- Package
- TSSOP-24
- Series
- データ取得 - アナログフロントエンド (AFE)
AD7730BRUZとAD7731BRUの詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。
Replacement verdict
The AD7731BRU is a functional replacement candidate for the AD7730BRUZ in many precision weigh-scale and low-frequency measurement designs, since both are pin-compatible 24-pin TSSOP sigma-delta ADCs with comparable resolution and supply requirements. However, the AD7730BRUZ integrates a dedicated bridge-excitation and AC-excitation feature set for load-cell applications, whereas the AD7731BRU is a general-purpose signal-conditioning ADC. Designers should validate the loss of bridge-specific excitation and the differences in output data rate and interface timing before substituting in bridge-sensor circuits.
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | AD7730BRUZ | AD7731BRU | Why it matters |
|---|---|---|---|
| Resolution (bits) | 24 | 24 | Both are 24-bit sigma-delta ADCs, so resolution alone does not distinguish them for substitutability. |
| Number of input channels | 2 differential | 3 differential | Channel count affects how many sensors or signal paths can be connected without external multiplexing. |
| Interface type | Serial (SPI-compatible) | Serial (SPI-compatible) | Both use a similar serial interface, easing firmware reuse when swapping parts. |
| Package / mounting | 24-TSSOP | 24-TSSOP | Identical package and footprint allow drop-in board replacement without layout changes. |
| Supply voltage (analog) | 5 V | 5 V | Matching analog supply requirements means the same power rail can be reused. |
| Input type / signal conditioning | Bridge/load-cell optimized with on-chip PGA | General-purpose with on-chip PGA | The AD7730 is tailored for weigh-scale bridge sensors, while the AD7731 is more general-purpose, affecting application fit. |
| Output data rate (max) | Up to 1.2 kSPS (programmable) | Up to 6.4 kSPS (programmable) | Higher output rate on the AD7731 supports faster sampling, which may matter for dynamic measurements. |
| On-chip features | Bridge excitation, burnout detection, AC excitation | PGA, calibration, burnout detection | Feature differences determine whether external circuitry is needed for a given sensor type. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | AD7730BRUZ | AD7731BRU |
|---|---|---|
| Supplier | - | Analog Devices Inc.,Rochester Electronics, LLC |
| Part Status | Active | Obsolete |
| Number of Bits | 24 | 24 |
| Sampling Rate(Per Second) | - | 6.4k |
| Number of Inputs | - | 3, 5 |
| Input Type | - | Differential |
| Data Interface | - | SPI, DSP |
| Configuration | - | MUX-PGA-ADC |
| Number of A/D Converters | - | 1 |
| Architecture | - | Sigma-Delta |
| Reference Type | - | External |
| Voltage - Supply, Analog | 5V | 5V |
| Voltage - Supply, Digital | 2.7V ~ 5.25V | 5V |
| Features | - | PGA |
| Operating Temperature | - | -40°C ~ 85°C |
| Number of Channels | 1 | - |
| Power (Watts) | 125 mW | - |
| Mounting Type | Surface Mount | - |
The AD7730BRUZ is a 24-bit sigma-delta load-cell ADC with on-chip PGA and AC excitation, while the AD7731BRU is a 24-bit sigma-delta ADC with a programmable gain front end but without the dedicated bridge/load-cell AC excitation circuitry. Both are supplied in 24-lead TSSOP packages, but they differ in their input signal conditioning and target applications.
Both devices are offered in a 24-lead TSSOP (RU) package, but pin functions are not identical. The AD7730BRUZ includes dedicated AC excitation and bridge-related pins, so a direct drop-in replacement should not be assumed. Pin assignments must be verified against the respective manufacturer datasheets before substitution.
Both the AD7730BRUZ and AD7731BRU are 24-bit sigma-delta (ΔΣ) analog-to-digital converters. The AD7730BRUZ is optimized for weigh-scale and load-cell applications, while the AD7731BRU is a general-purpose high-resolution sigma-delta ADC with programmable gain.
Yes. Both the AD7730BRUZ and AD7731BRU integrate a programmable gain front end, allowing direct connection of low-level sensor signals. The gain settings and input ranges should be confirmed from the respective datasheets for the specific design.
The AD7730BRUZ is specifically designed for weigh-scale and load-cell applications, featuring AC excitation and bridge-related signal conditioning. The AD7731BRU is a general-purpose high-resolution ADC and lacks the dedicated load-cell excitation circuitry, so the AD7730BRUZ is the more application-specific choice for bridge sensor designs.
Both devices are available in a 24-lead TSSOP package, indicated by the "RU" suffix in their part numbers. PCB land patterns and thermal considerations should be verified against the manufacturer datasheets.
Substitution is not straightforward. Because the AD7730BRUZ includes dedicated AC excitation and bridge signal-conditioning features that the AD7731BRU does not, a replacement requires validating input configuration, excitation requirements, and pin functions against both datasheets before use in a target design.