AD7890ARZ-10
テキサス・インスツルメンツ
- Lifecycle
- Active
- Stock
- 6285 個数
- Package
- SOIC-24
- Series
- データ取得 - ADC/DAC - 特殊用途向け
AD7890ARZ-10とAD7899SR-1の詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。
Replacement verdict
The AD7890ARZ-10 and AD7899SR-1 are not drop-in replacements for one another. Although both are Analog Devices 14-bit successive-approximation ADCs, they differ in channel configuration, digital interface, package footprint, and specified operating temperature range, so a direct board-level substitution is not possible without redesign.
テキサス・インスツルメンツ
テキサス・インスツルメンツ
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | AD7890ARZ-10 | AD7899SR-1 | Why it matters |
|---|---|---|---|
| Resolution | 12 bit | 14 bit | Higher resolution provides finer quantization steps, improving measurement accuracy and dynamic range for precision applications. |
| Number of ADC Inputs / Channels | 8 (single-ended, multiplexed) | 1 (single-ended) | Channel count determines how many analog signals can be digitized; a multiplexed 8-channel part suits multi-signal systems, while a single-channel part suits dedicated high-speed conversion. |
| Sampling Rate | 105 kSPS | 400 kSPS | Maximum throughput limits the bandwidth of signals that can be captured and affects suitability for fast or multiplexed acquisition systems. |
| Input Voltage Range | ±10 V (bipolar) | ±2.5 V (bipolar) | The input span must match the sensor or signal amplitude; a ±10 V range suits industrial signals while ±2.5 V suits lower-level signals requiring finer LSB size. |
| Interface Type | Serial (SPI-compatible) | Parallel | The digital interface must be compatible with the host controller; serial saves pins while parallel offers higher data throughput. |
| Supply Voltage | 5 V (single supply) | 5 V (single supply) | Supply voltage compatibility ensures the part can be powered from the existing rail without additional regulation. |
| Package / Mounting | 24-lead SOIC (surface mount) | 28-lead SSOP (surface mount) | Package footprint and pin count affect PCB layout and whether a drop-in replacement is possible without board redesign. |
| Operating Temperature Range | -40 °C to +85 °C (industrial) | -55 °C to +125 °C (extended/military) | Temperature grade determines suitability for harsh or military environments versus standard industrial conditions. |
| Architecture | SAR (successive approximation) | SAR (successive approximation) | Converter architecture influences latency, power, and behavior in multiplexed or control-loop applications. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | AD7890ARZ-10 | AD7899SR-1 |
|---|---|---|
| Supplier | - | Analog Devices Inc.,Rochester Electronics, LLC |
| Part Status | Active | Obsolete |
| Number of Bits | - | 14 |
| Sampling Rate(Per Second) | 117k | 400k |
| Number of Inputs | - | 1 |
| Input Type | - | Single Ended |
| Data Interface | SPI | Parallel |
| Configuration | - | S/H-ADC |
| Ratio - S / H: ADC | - | 1:1 |
| Number of A/D Converters | - | 1 |
| Architecture | - | SAR |
| Reference Type | - | External, Internal |
| Voltage - Supply, Analog | - | 5V |
| Voltage - Supply, Digital | - | 5V |
| Operating Temperature | -40°C ~ 85°C | -55°C ~ 125°C |
| Type | Data Acquisition System (DAS) | - |
| Number of Channels | 8 | - |
| Resolution(Bits) | 12 b | - |
| Voltage Supply Source | Single Supply | - |
| Voltage - Supply | 5V | - |
| Mounting Type | Surface Mount | - |
The AD7890ARZ-10 is an 8-channel, 12-bit successive-approximation ADC with a serial interface, specified for operation from 0°C to 70°C in a 24-lead SOIC package. The AD7899SR-1 is a single-channel, 14-bit ADC with a parallel interface, specified for operation from -55°C to 125°C in a 28-lead SOIC package. They differ in resolution, channel count, interface type, temperature grade, and package pinout.
No. The two devices have different pin counts (24-lead vs 28-lead SOIC), different interface types (serial vs parallel), different resolutions (12-bit vs 14-bit), and different channel counts (8-channel vs single-channel). A direct drop-in substitution is not possible without a PCB redesign and system-level revalidation.
The AD7890ARZ-10 provides 12-bit resolution with an 8-channel input multiplexer. The AD7899SR-1 provides 14-bit resolution with a single analog input channel. These differences make the AD7890ARZ-10 suited to multi-channel monitoring, while the AD7899SR-1 targets higher-accuracy single-channel acquisition.
The AD7890ARZ-10 uses a serial digital interface for data output and configuration. The AD7899SR-1 uses a parallel digital interface for data output. System designers must account for these interface differences when selecting a host processor or FPGA and when laying out the digital bus.
The AD7890ARZ-10 is specified for the commercial temperature range of 0°C to 70°C. The AD7899SR-1 is specified for the extended/industrial temperature range of -55°C to 125°C. The AD7899SR-1 is therefore the appropriate choice for wide-temperature or harsh-environment applications.
No. The AD7890ARZ-10 is supplied in a 24-lead SOIC package, while the AD7899SR-1 is supplied in a 28-lead SOIC package. The pin counts and pin functions differ, so the PCB footprint and land pattern must be designed specifically for each device.
The AD7890ARZ-10 is better suited for multi-channel data acquisition because it integrates an 8-channel input multiplexer with a 12-bit ADC and a serial interface, reducing external component count. The AD7899SR-1, with a single input channel, is intended for applications requiring one high-accuracy 14-bit conversion path.
A migration requires verification of resolution and accuracy requirements, channel count, interface compatibility (serial vs parallel), package footprint and pinout, supply and reference requirements, and operating temperature range. All differences must be validated against the respective Analog Devices datasheets before any redesign is committed.