AD7894ARZ-3 vs AD7890BR-4

AD7894ARZ-3とAD7890BR-4の詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The AD7894ARZ-3 and AD7890BR-4 are not drop-in replacements for one another. Although both are Analog Devices AD789x-family successive-approximation ADCs, they differ in resolution, channel architecture, package footprint, and serial interface configuration, so a direct board-level substitution is not possible without redesign.

Different resolution Different channel count Different package footprint Different interface configuration

Parts at a glance

Part A

AD7894ARZ-3

テキサス・インスツルメンツ

Lifecycle
Active
Stock
3263 個数
Package
SOIC-8
Series
データ取得 - アナログ/デジタルコンバータ (ADC)
Part B

AD7890BR-4

テキサス・インスツルメンツ

Lifecycle
Active
Stock
9357 個数
Package
SOIC-24
Series
データ取得 - ADC/DAC - 特殊用途向け

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AD7894ARZ-3 AD7890BR-4 Why it matters
Resolution (bits) 14 12 Resolution determines the smallest measurable signal step; a 14-bit ADC offers finer quantization than a 12-bit device, affecting measurement precision and substitutability.
Number of ADC channels 1 (single-ended) 8 (single-ended, multiplexed) Channel count defines how many analog inputs can be digitized; a single-channel part cannot directly replace a multiplexed 8-channel part in multi-signal systems.
Sampling rate (max) 200 kSPS 117 kSPS Maximum throughput limits the highest signal frequency that can be captured; differing rates affect suitability for fast or multiplexed acquisition designs.
Input voltage range ±10 V (bipolar) ±10 V (bipolar) Input range must match the sensor or signal amplitude; both accept ±10 V, so front-end scaling requirements are similar.
Supply voltage 5 V (single supply) 5 V (single supply) Supply voltage compatibility determines whether the part can drop into an existing power rail without redesign.
Digital interface Serial (SPI/QSPI compatible) Serial (SPI/QSPI compatible) Interface type must match the host controller; both use a serial interface, easing firmware-level substitution.
Package 20-lead SOIC (W) 24-lead SOIC (W) Package footprint and pin count affect PCB layout; different packages require board redesign and cannot be directly swapped.
Operating temperature range -40 °C to +85 °C -40 °C to +85 °C Temperature range must cover the application environment; matching industrial ranges supports similar deployment conditions.
Internal reference Yes (on-chip reference) Yes (on-chip reference) An internal reference simplifies system design and reduces external components; both providing one supports comparable accuracy without extra circuitry.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AD7894ARZ-3 AD7890BR-4
Supplier - Analog Devices Inc.,Rochester Electronics, LLC
Part Status Active Obsolete
Type - Data Acquisition System (DAS)
Number of Channels - 8
Resolution(Bits) - 12 b
Sampling Rate(Per Second) 200k 117k
Data Interface SPI Serial
Voltage Supply Source - Single Supply
Voltage - Supply - 5V
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C
Mounting Type - Surface Mount
Number of Bits 14 -
Number of Inputs 1 -
Input Type Single Ended -
Configuration S/H-ADC -
Ratio - S / H: ADC 1:1 -
Number of A/D Converters 1 -
Architecture SAR -
Reference Type External -
Voltage - Supply, Analog 5V -
Voltage - Supply, Digital 5V -

Frequently asked questions

What are the key architectural differences between the AD7894ARZ-3 and AD7890BR-4?

The AD7894ARZ-3 is a 14-bit successive-approximation ADC with a single input channel and a serial interface, housed in a 24-lead SOIC package. The AD7890BR-4 is a 12-bit data-acquisition system that integrates an 8-channel input multiplexer, a track-and-hold amplifier, and a successive-approximation ADC with a serial interface, housed in a 24-lead SOIC package. The AD7894ARZ-3 provides higher resolution on a single channel, while the AD7890BR-4 provides multi-channel acquisition at lower resolution.

Do the AD7894ARZ-3 and AD7890BR-4 have the same resolution and accuracy specifications?

No. The AD7894ARZ-3 is specified as a 14-bit ADC, while the AD7890BR-4 is specified as a 12-bit data-acquisition system. The AD7894ARZ-3 therefore offers finer quantization resolution than the AD7890BR-4. Designers should consult the respective manufacturer datasheets for detailed linearity, offset, gain, and total unadjusted error specifications, as these differ between the two devices.

How do the input configurations of the AD7894ARZ-3 and AD7890BR-4 differ?

The AD7894ARZ-3 provides a single analog input channel, making it suited to single-channel measurement applications. The AD7890BR-4 integrates an 8-channel multiplexer, allowing it to sequentially acquire from up to eight analog input channels through one converter. This makes the AD7890BR-4 preferable for multi-channel data-acquisition systems, while the AD7894ARZ-3 is preferable when only one channel is required.

Are the AD7894ARZ-3 and AD7890BR-4 pin-compatible or directly interchangeable?

No. Although both devices are offered in 24-lead SOIC packages, they are different functional architectures with different pin functions and internal signal paths. The AD7894ARZ-3 is a single-channel ADC, whereas the AD7890BR-4 includes an 8-channel multiplexer and associated control logic. They should not be treated as drop-in replacements; any substitution requires full validation against the manufacturer datasheets and the target design.

What supply voltage and reference requirements apply to the AD7894ARZ-3 and AD7890BR-4?

Both devices are specified for 5 V operation with an external reference input, but the exact reference voltage range, supply tolerance, and power consumption differ between the two products. The AD7894ARZ-3 and AD7890BR-4 each require the reference and supply conditions stated in their respective manufacturer datasheets. Designers must verify the reference voltage, supply range, and decoupling requirements from the official datasheet before finalizing a design.

Which device is better suited for multi-channel data acquisition, and which for high-resolution single-channel measurement?

The AD7890BR-4 is better suited for multi-channel data acquisition because it integrates an 8-channel multiplexer with a 12-bit ADC in a single package. The AD7894ARZ-3 is better suited for high-resolution single-channel measurement because it provides 14-bit resolution on a single input channel. The choice depends on whether channel count or resolution is the dominant system requirement.

Do the AD7894ARZ-3 and AD7890BR-4 use the same digital interface?

Both devices provide a serial digital interface, but the interface timing, control word structure, and data format differ because the AD7890BR-4 includes multiplexer channel selection and conversion control logic, while the AD7894ARZ-3 is a single-channel converter. The serial clock rate, frame timing, and control register behavior must be taken from each device's respective datasheet and cannot be assumed to be identical.

What package and operating temperature range do the AD7894ARZ-3 and AD7890BR-4 share?

Both the AD7894ARZ-3 and AD7890BR-4 are offered in 24-lead SOIC packages and are specified for the industrial temperature range of −40 °C to +85 °C, as stated in their manufacturer datasheets. Package outline, lead finish, and thermal characteristics should be confirmed against the official datasheet for each specific orderable part number before board layout and assembly.