AD8228BRZ vs AD8223AR

AD8228BRZとAD8223ARの詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The AD8228BRZ and AD8223AR are both single-channel instrumentation amplifiers in SOIC-8 packages, but they differ in gain programming architecture, supply range, and bandwidth. The AD8228BRZ offers pin-selectable gains of 10 or 100 with wider supply and bandwidth, while the AD8223AR uses a single external resistor for gain setting with a narrower supply range. Designers should validate gain configuration, supply rails, and dynamic performance before substituting.

Amplifier Architecture Validation required
Gain Programming Method Validation required
Supply Voltage Range Validation required
Package Type High match

Parts at a glance

Part A

AD8228BRZ

テキサス・インスツルメンツ

Lifecycle
Active
Stock
3991 個数
Package
SOIC-8
Series
リニアアンプ - 計装用、オペアンプ、バッファアンプ
Part B

AD8223AR

テキサス・インスツルメンツ

Lifecycle
Active
Stock
3886 個数
Package
SOIC-8
Series
リニアアンプ - 計装用、オペアンプ、バッファアンプ

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AD8228BRZ AD8223AR Why it matters
Number of Amplifiers 1 1 Both are single instrumentation amplifiers, so channel count is compatible for single-channel signal conditioning designs.
Gain Setting Method Pin-selectable fixed gains (G = 10 or 100) External resistor programmable gain Determines how gain is configured; fixed-gain parts simplify design while resistor-programmable parts offer flexible gain ranges.
Gain Range 10 or 100 (fixed) Programmable via external resistor (up to ~1000) Affects the achievable signal amplification and whether the part suits a specific sensor output range.
Supply Voltage Range ±2.3 V to ±18 V (dual supply) ±2 V to ±18 V (dual supply) Defines compatibility with the system power rails and headroom available for signal swing.
Input Offset Voltage (max) ±50 µV (B grade) ±250 µV (A grade) Lower offset improves DC accuracy; the B-grade AD8228 offers tighter offset than the A-grade AD8223.
Input Offset Voltage Drift 0.5 µV/°C (typ) 2 µV/°C (typ) Drift affects accuracy over temperature; lower drift is preferable for precision measurement applications.
Input Bias Current 0.5 nA (typ) 25 nA (typ) Low bias current reduces errors with high-impedance sources; the AD8228 is better suited to high-impedance sensors.
Gain Bandwidth Product 1 MHz (G = 10) 1 MHz Determines the bandwidth available at a given gain, affecting dynamic signal fidelity.
Common-Mode Rejection Ratio (CMRR) 100 dB (G = 10, typ) 86 dB (G = 10, typ) Higher CMRR rejects common-mode noise and interference, improving measurement accuracy in noisy environments.
Operating Temperature Range -40 °C to +85 °C -40 °C to +85 °C Confirms both parts are rated for the same industrial temperature envelope for environmental compatibility.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AD8228BRZ AD8223AR
Supplier - Rochester Electronics, LLC,Analog Devices Inc.
Part Status Active Obsolete
Amplifier Type Instrumentation Instrumentation
Number of Circuits 1 1
Output Type - Rail-to-Rail
Slew Rate 2.5V/µs 0.3V/µs
-3 dB Bandwidth 650 kHz 200 kHz
Current - Input Bias 400 pA 12 nA
Voltage - Input Offset 50 µV 250 µV
Supply Current 850µA 650µA
Voltage - Supply Span(Min) 4.6 V 3 V
Voltage - Supply Span(Max) 36 V 24 V
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C
Mounting Type Surface Mount Surface Mount
Current - Output / Channel 18 mA -

Frequently asked questions

What are the primary functional differences between the AD8228BRZ and the AD8223AR?

The AD8228BRZ is a low-drift, high-accuracy instrumentation amplifier with a fixed gain of 10, specified for a maximum input offset voltage of 50 µV and an offset drift of 0.5 µV/°C. The AD8223AR is a single-supply, rail-to-rail output instrumentation amplifier with a programmable gain set by a single external resistor (G = 5 to 1000), specified for a maximum input offset voltage of 250 µV. The AD8228BRZ targets precision DC applications, while the AD8223AR targets single-supply, space-constrained signal conditioning.

Are the AD8228BRZ and AD8223AR pin-compatible?

No. The AD8228BRZ is supplied in an 8-lead SOIC package (R-8 suffix), while the AD8223AR is supplied in an 8-lead MSOP package (RM-8 suffix). The package body dimensions and PCB land patterns differ, so they are not drop-in replacements without a board layout change.

Can the AD8228BRZ and AD8223AR be used as direct substitutes in an existing design?

No. The AD8228BRZ has a fixed gain of 10, whereas the AD8223AR requires an external gain-setting resistor and supports gains from 5 to 1000. In addition, the AD8228BRZ is specified for dual-supply operation (±5 V to ±15 V), while the AD8223AR is optimized for single-supply operation (3 V to 12 V). Gain configuration, supply topology, and package footprint must all be revalidated before any substitution.

How do the input offset voltage and drift specifications compare?

The AD8228BRZ (B grade) specifies a maximum input offset voltage of 50 µV with a maximum offset drift of 0.5 µV/°C. The AD8223AR (A grade) specifies a maximum input offset voltage of 250 µV; its datasheet offset drift is typically 2 µV/°C. The AD8228BRZ therefore offers roughly five times better offset accuracy and lower drift for precision DC instrumentation.

What supply voltage ranges do the AD8228BRZ and AD8223AR support?

The AD8228BRZ operates from dual supplies of ±5 V to ±15 V (10 V to 30 V total). The AD8223AR operates from a single supply of 3 V to 12 V, and can also be used with dual supplies within that total range. Designs migrating between the two must verify that the available supply rails fall within the target device's specified range.

How is gain configured on each device?

The AD8228BRZ has a fixed gain of 10 set internally; no external gain resistor is required or supported. The AD8223AR uses a single external resistor connected between its RG pins to set gain according to G = 5 + (200 kΩ / RG), allowing gains from 5 to 1000. This is a fundamental architectural difference that affects both circuit design and BOM content.

Which device is better suited for single-supply, low-voltage signal conditioning?

The AD8223AR is the appropriate choice for single-supply, low-voltage systems because it is specified from 3 V to 12 V single supply with rail-to-rail output swing. The AD8228BRZ is specified for dual supplies of ±5 V to ±15 V and is not characterized for 3 V single-supply operation, so it is not suitable for low-voltage single-supply designs.

Do the AD8228BRZ and AD8223AR share the same operating temperature range?

Both devices are specified over the industrial temperature range of −40°C to +85°C. The AD8228BRZ is also available in an extended grade (AD8228ARZ/BRZ variants) covering −40°C to +125°C, while the AD8223AR is specified for −40°C to +85°C. Designs requiring operation above +85°C should verify the specific grade selected.