ADF4107BRU
テキサス・インスツルメンツ
- Lifecycle
- Active
- Stock
- 2399 個数
- Series
- クロックタイミング - クロックジェネレータ、PLL、周波数シンセサイザ
ADF4107BRUとADF4112BRUの詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。
Replacement verdict
The ADF4107BRU and ADF4112BRU are both single PLL frequency synthesizers in the same 16-lead TSSOP package and share a common interface and supply architecture, making the ADF4112BRU a viable functional replacement candidate for the ADF4107BRU in many designs. However, the two devices differ in maximum operating frequency and RF input sensitivity, so the replacement should be validated against the target frequency plan and loop filter design before adoption.
テキサス・インスツルメンツ
テキサス・インスツルメンツ
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADF4107BRU | ADF4112BRU | Why it matters |
|---|---|---|---|
| Maximum RF Input Frequency | 4 GHz | 3 GHz | Determines the highest frequency the PLL synthesizer can operate at; the ADF4107 supports higher-frequency applications. |
| Maximum PFD (Phase Frequency Detector) Frequency | 104 MHz | 55 MHz | Higher PFD frequency enables wider loop bandwidth and faster lock times; affects phase noise and settling performance. |
| RF Input Frequency Range (minimum) | 0.5 GHz | 0.5 GHz | Defines the lower bound of usable input frequency; both share the same lower limit here. |
| Supply Voltage Range | 2.7 V to 3.3 V | 2.7 V to 3.3 V | Both operate from the same supply range, allowing similar power supply design and compatibility. |
| Package | 16-Lead TSSOP | 16-Lead TSSOP | Identical package footprint enables drop-in board-level substitution without layout changes. |
| Number of Programmable Counters / Modulus | Dual-modulus prescaler 8/9, 16/17, 32/33, 64/65 | Dual-modulus prescaler 8/9, 16/17, 32/33, 64/65 | Same prescaler options provide flexibility in loop divider ratios for various frequency planning needs. |
| Charge Pump Current (programmable) | Up to 5 mA | Up to 5 mA | Charge pump current affects loop filter design and lock time; matching values simplify substitution. |
| Operating Temperature Range | -40 °C to +85 °C | -40 °C to +85 °C | Identical temperature ratings ensure equivalent environmental robustness for industrial applications. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADF4107BRU | ADF4112BRU |
|---|---|---|
| Supplier | - | Analog Devices Inc.,Rochester Electronics, LLC |
| Part Status | Obsolete | Obsolete |
| Type | Clock/Frequency Synthesizer (RF) | Clock/Frequency Synthesizer (RF) |
| PLL | Yes | Yes |
| Input | CMOS, TTL | CMOS, TTL |
| Output | Clock | Clock |
| Number of Circuits | 1 | 1 |
| Ratio - Input: Output | 2:1 | 2:1 |
| Differential - Input: Output | Yes/No | Yes/No |
| Frequency - Max | 7GHz | 3GHz |
| Divider / Multiplier | No/No | Yes/No |
| Voltage - Supply | 2.7V ~ 3.3V | 2.7V ~ 5.5V |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 85°C |
| Mounting Type | Surface Mount | Surface Mount |
| Base Product Number | ADF4107 | - |
| Digi Key Programmable | Not Verified | - |
| Packaging | Tube | - |
Both are Analog Devices integer-N PLL frequency synthesizers in 16-lead TSSOP packages, but they differ in maximum RF input frequency and prescaler architecture. The ADF4107 operates up to 7 GHz with a 4/5 or 8/9 dual-modulus prescaler, while the ADF4112 operates up to 3 GHz with a fixed 8/9 prescaler. The ADF4107 also supports a wider RF input range and higher PFD frequency, making it suited to higher-frequency applications.
Yes. Both devices are offered in the same 16-lead TSSOP (RU suffix) package and share a common pinout for the serial interface, charge pump, reference input, and RF inputs. This allows a common PCB footprint, but firmware and loop filter values must be revalidated because the prescaler and frequency ranges differ.
The ADF4107 is specified for RF input frequencies up to 7 GHz. The ADF4112 is specified for RF input frequencies up to 3 GHz. Designs requiring operation above 3 GHz must use the ADF4107 or another device rated for the target frequency.
No. The ADF4107 uses a dual-modulus prescaler selectable as 4/5 or 8/9. The ADF4112 uses a fixed 8/9 prescaler. This affects the modulus, the achievable channel spacing, and the register programming values, so configuration code cannot be reused without modification.
Not unconditionally. Although the package and pinout are compatible, the ADF4112 has a lower maximum RF input frequency (3 GHz versus 7 GHz) and a different prescaler. A drop-in replacement is only valid if the target design operates within the ADF4112 frequency range and the loop filter and register settings are recalculated and verified.
Both the ADF4107 and ADF4112 operate from a nominal 3 V supply (2.7 V to 3.3 V range) and use a three-wire serial interface (CLK, DATA, LE) for register programming. They also share a similar charge pump and reference input architecture, which simplifies migration between the two when frequency requirements permit.
The ADF4107BRU should be selected, because its RF input is specified up to 7 GHz. The ADF4112BRU is limited to 3 GHz and is not rated for 5 GHz operation. Selection must also account for prescaler, PFD frequency, and loop filter design.