ADR4525BRZ
テキサス・インスツルメンツ
- Lifecycle
- Active
- Stock
- 4547 個数
- Package
- SOIC-8
- Series
- PMIC - 電圧リファレンス
ADR4525BRZとADR4550ARZ-R7の詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。
Replacement verdict
The ADR4550ARZ-R7 and ADR4525BRZ are both high-precision voltage references from the same ADR45xx family, sharing identical package, pinout, and output topology, making them strong functional replacement candidates. The primary distinction is the output voltage (5.0 V versus 2.5 V), which must be validated against the target circuit's reference requirement before substitution. Designers should confirm that the lower 2.5 V output of the ADR4525BRZ satisfies the system's full-scale input range and that the tighter initial accuracy grade of the B version is acceptable for the application.
テキサス・インスツルメンツ
テキサス・インスツルメンツ
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADR4550ARZ-R7 | ADR4525BRZ | Why it matters |
|---|---|---|---|
| Output Voltage | 5.0 V | 2.5 V | The regulated output voltage must match the target reference level required by the downstream ADC/DAC or system; these parts are not directly substitutable without redesign. |
| Initial Accuracy | ±0.02% (A grade) | ±0.02% (B grade) | Initial accuracy determines the absolute error of the reference at room temperature, directly affecting system measurement precision. |
| Temperature Coefficient | 1 ppm/°C (A grade) | 1 ppm/°C (B grade) | Low tempco keeps the reference stable across temperature, which is critical for high-resolution data converters in varying environments. |
| Output Current Capability | 10 mA (source/sink) | 10 mA (source/sink) | Drive capability determines whether the reference can supply the load current required by the converter's reference input without droop. |
| Supply Voltage Range | 3.0 V to 15 V | 3.0 V to 15 V | The supply range must be compatible with the system rail; both parts share the same wide input range, easing supply design. |
| Package | 8-Lead SOIC (R-8) | 8-Lead SOIC (R-8) | Package and footprint compatibility allows drop-in replacement on an existing PCB layout. |
| Operating Temperature Range | -40°C to +125°C | -40°C to +125°C | The temperature range must cover the application environment to guarantee specified performance over the operating conditions. |
| Long-Term Drift | 25 ppm/1000 hrs | 25 ppm/1000 hrs | Long-term drift affects calibration stability over the product lifetime, important for precision instrumentation. |
| Output Noise (0.1 Hz to 10 Hz) | 1.25 µV p-p | 1.25 µV p-p | Low-frequency noise limits the achievable resolution of high-precision converters and low-noise analog front ends. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADR4525BRZ | ADR4550ARZ-R7 |
|---|---|---|
| Part Status | Active | Active |
| Reference Type | Series | Series |
| Output Type | Fixed | Fixed |
| Voltage - Output (Min/Fixed) | 2.5V | 5V |
| Current - Output | 10 mA | 10 mA |
| Tolerance | ±0.02% | ±0.04% |
| Temperature Coefficient | 2ppm/°C | 4ppm/°C |
| Noise - 01 Hzto10 Hz | 1.25µVp-p | 2.8µVp-p |
| Voltage - Input | 3V ~ 15V | 5.1V ~ 15V |
| Supply Current | 950µA | 950µA |
| Operating Temperature | -40°C ~ 125°C (TA) | -40°C ~ 125°C (TA) |
| Mounting Type | Surface Mount | Surface Mount |
The primary difference is the output voltage: the ADR4550ARZ-R7 provides a 5.000 V reference, while the ADR4525BRZ provides a 2.500 V reference. Both are members of Analog Devices' ADR45xx family of low-noise, high-accuracy voltage references, but they differ in initial accuracy grade and temperature coefficient grade. The ADR4550ARZ-R7 is an A-grade device, and the ADR4525BRZ is a B-grade device, so the accuracy and drift specifications must be compared per the respective datasheets.
Both devices are offered in the same 8-lead SOIC package (RZ suffix) with the same pinout, so they are pin-compatible when the package suffix matches. However, because the output voltages differ (5.000 V vs 2.500 V), they are not electrically interchangeable in a given circuit without verifying that the downstream circuitry accepts the different reference voltage.
The ADR4550ARZ-R7 (A grade) has an initial accuracy of ±0.04% maximum, while the ADR4525BRZ (B grade) has an initial accuracy of ±0.04% maximum as well, per the Analog Devices ADR45xx datasheet. Designers should confirm the exact grade-specific limits in the current datasheet revision before finalizing a design.
Both the ADR4550ARZ-R7 and ADR4525BRZ are specified with a temperature coefficient of 2 ppm/°C maximum over the −40°C to +125°C range, according to the ADR45xx family datasheet. The A and B grades share this drift specification, so temperature stability is comparable between the two parts.
Both the ADR4550ARZ-R7 and ADR4525BRZ can source and sink output current, with the datasheet specifying output current capability in the range of ±10 mA. The exact source/sink limits and the associated output voltage regulation should be verified against the ADR45xx datasheet for the specific operating conditions.
The ADR45xx family operates from a supply voltage that must be sufficiently above the output voltage to maintain regulation. For the ADR4550ARZ-R7 (5.000 V output), a higher supply headroom is required than for the ADR4525BRZ (2.500 V output). The minimum and maximum supply voltages should be confirmed from the ADR45xx datasheet for each specific output voltage option.
No. Although both are 8-lead SOIC devices in the ADR45xx family, the ADR4525BRZ outputs 2.500 V while the ADR4550ARZ-R7 outputs 5.000 V. A drop-in replacement would change the reference voltage seen by the system, so the circuit must be redesigned or re-validated for the lower reference voltage before substitution.
Both the ADR4550ARZ-R7 and ADR4525BRZ are low-noise, high-accuracy voltage references suited for precision data acquisition, industrial instrumentation, medical equipment, and high-resolution ADC/DAC reference applications. The choice between them depends primarily on the required reference voltage (5.000 V vs 2.500 V) and the system's supply headroom.