ADS1222IPWR vs ADS1203IPWRG4

ADS1222IPWRとADS1203IPWRG4の詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS1222IPWR and ADS1203IPWRG4 are not drop-in replacements for one another. Although both are 24-bit delta-sigma analog-to-digital converters in TSSOP packages, they differ fundamentally in resolution architecture, output interface, channel configuration, and modulator clock requirements, so a direct board-level substitution is not feasible without redesign.

Different output interface Different channel configuration Different modulator clock scheme Different conversion architecture

Parts at a glance

Part A

ADS1222IPWR

STマイクロエレクトロニクス

Lifecycle
Active
Stock
3095 個数
Package
TSSOP-14
Series
データ取得 - アナログ/デジタルコンバータ (ADC)
Part B

ADS1203IPWRG4

STマイクロエレクトロニクス

Lifecycle
Active
Stock
4572 個数
Package
TSSOP-8
Series
データ取得 - ADC/DAC - 特殊用途向け

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1222IPWR ADS1203IPWRG4 Why it matters
Resolution (bits) 24 16 Resolution determines the smallest signal change the ADC can distinguish; a 24-bit device offers far finer measurement granularity than a 16-bit device.
Architecture Delta-Sigma (24-bit ADC) Delta-Sigma modulator The ADS1222 is a complete ADC with digital filter and interface, while the ADS1203 is a modulator-only device requiring external digital filtering, affecting system design and substitutability.
Output Interface SPI (serial) 1-bit modulator bitstream The output format dictates how the host processor receives data; SPI provides ready-to-use conversion results, whereas a bitstream requires an external sinc filter.
Input Channels 2 differential 1 differential Channel count determines how many signals can be measured; the ADS1222 supports two differential inputs while the ADS1203 supports only one.
Supply Voltage (analog) 2.7 V to 5.5 V 4.5 V to 5.5 V The wider supply range of the ADS1222 allows operation at lower voltages, while the ADS1203 requires a nominal 5 V supply, affecting power-supply compatibility.
Package TSSOP-16 TSSOP-16 Package footprint affects PCB layout and drop-in compatibility; both share the same TSSOP-16 footprint, easing board-level substitution.
Operating Temperature Range -40 °C to +85 °C -40 °C to +85 °C The temperature range defines the environments in which the device can reliably operate; identical ranges mean equivalent environmental robustness.
Data Rate / Modulator Clock Up to 2 kSPS (programmable) Up to 10 MHz modulator clock Throughput and clocking scheme differ significantly; the ADS1222 offers programmable output data rates while the ADS1203 relies on an external modulator clock, impacting system timing design.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1222IPWR ADS1203IPWRG4
Supplier - Texas Instruments
Part Status Active Obsolete
Type - Modulator
Number of Channels - 1
Resolution(Bits) - 16 b
Sampling Rate(Per Second) 240 40k
Data Interface SPI Serial
Voltage Supply Source - Single Supply
Voltage - Supply - 4.75V ~ 5.25V
Operating Temperature -40°C ~ 85°C -40°C ~ 125°C
Mounting Type - Surface Mount
Number of Bits 24 -
Number of Inputs 2 -
Input Type Differential, Single Ended -
Configuration MUX-ADC -
Number of A/D Converters 1 -
Architecture Sigma-Delta -
Reference Type External -
Voltage - Supply, Analog 2.7V ~ 5.5V -
Voltage - Supply, Digital 2.7V ~ 5.5V -
Features Temperature Sensor -

Frequently asked questions

What are the primary functional differences between the ADS1222IPWR and ADS1203IPWRG4?

The ADS1222IPWR is a 24-bit delta-sigma analog-to-digital converter with a two-channel differential input multiplexer, internal oscillator, and a programmable gain amplifier, housed in a TSSOP-16 package. The ADS1203IPWRG4 is a 16-bit delta-sigma modulator with a single differential input, designed for isolated signal acquisition when paired with an external digital filter, and is supplied in a TSSOP-8 package. The ADS1222 integrates a full ADC with digital filter, while the ADS1203 outputs a 1-bit modulator stream requiring external processing.

Are the ADS1222IPWR and ADS1203IPWRG4 pin-compatible or package-compatible?

No. The ADS1222IPWR uses a TSSOP-16 package, whereas the ADS1203IPWRG4 uses a smaller TSSOP-8 package. The pin counts, pin functions, and PCB land patterns differ, so these devices are not drop-in replacements for each other.

What are the resolution and output data format differences between the two devices?

The ADS1222IPWR provides 24-bit resolution and outputs fully processed digital codes via its serial interface after internal digital filtering. The ADS1203IPWRG4 is a 16-bit delta-sigma modulator that outputs a 1-bit serial bitstream at a high oversampling rate; the effective 16-bit resolution is achieved only after external digital filtering (e.g., in an FPGA or DSP).

Do both devices support the same supply voltage range?

Both devices operate from a single 5 V analog supply (AVDD = 5 V typical) with a separate digital supply (DVDD) that supports 2.7 V to 5.5 V logic interfaces, per their respective manufacturer datasheets. Designers should verify the exact recommended operating conditions in the latest datasheet revision before finalizing the supply design.

Which device is better suited for isolated current-sense or shunt-based measurement applications?

The ADS1203IPWRG4 is specifically intended for isolated signal acquisition: its modulator output can be routed across an isolation barrier to a digital filter, making it suitable for isolated shunt-based current sensing in motor drives and power inverters. The ADS1222IPWR integrates the digital filter and is better suited for non-isolated, general-purpose precision sensor measurement where a complete ADC solution is desired.

Can the ADS1203IPWRG4 be used as a direct substitute for the ADS1222IPWR in an existing design?

No. Beyond the package and pin-count differences, the ADS1203IPWRG4 requires an external digital filter to produce usable conversion results, whereas the ADS1222IPWR delivers filtered digital output directly. Substitution would require redesign of the signal chain, PCB layout, and firmware, and must be validated against the manufacturer datasheets.

What are the input channel configurations of each device?

The ADS1222IPWR features a two-channel differential input multiplexer, allowing selection between two differential input pairs. The ADS1203IPWRG4 has a single differential input pair. Designs requiring multiple input channels should account for this difference when selecting between the two parts.