ADS1246IPW vs ADS1282HIPW

ADS1246IPWとADS1282HIPWの詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS1246IPW and ADS1282HIPW are not functionally interchangeable. The ADS1246IPW is a 24-bit, 2 kSPS delta-sigma ADC with a single differential input and an SPI interface, while the ADS1282HIPW is a 31-bit, 4 kSPS delta-sigma ADC with dual differential inputs, a built-in PGA, and a different pinout and supply architecture. The differences in resolution, sample rate, channel count, and package pinout prevent direct substitution without a full redesign of the signal chain and board layout.

Different resolution and sample rate Different channel count Different package pinout Different supply architecture

Parts at a glance

Part A

ADS1246IPW

STマイクロエレクトロニクス

Lifecycle
Active
Stock
6549 個数
Package
TSSOP-16
Series
データ取得 - アナログ/デジタルコンバータ (ADC)
Part B

ADS1282HIPW

STマイクロエレクトロニクス

Lifecycle
Active
Stock
6044 個数
Package
TSSOP-28
Series
データ取得 - アナログ/デジタルコンバータ (ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1246IPW ADS1282HIPW Why it matters
Resolution (bits) 24 31 Higher resolution enables finer measurement of small signal changes, which is critical for precision seismic and high-dynamic-range applications.
Number of input channels 1 (single-ended/differential) 2 (differential) Channel count determines how many signal sources can be measured without external multiplexing.
Maximum sample rate 2 kSPS 4 kSPS Sample rate limits the bandwidth of signals that can be captured and affects anti-aliasing requirements.
PGA gain range 1 to 128 1 to 64 Programmable gain allows small-amplitude signals to be amplified to use the full ADC range, improving effective resolution.
Supply voltage 2.7 V to 5.25 V (analog and digital) 5 V analog, 1.8 V to 3.3 V digital Supply requirements determine power-rail compatibility and whether level shifting is needed in a given system.
Interface type SPI SPI Both use SPI, so the host microcontroller interface is compatible, but register maps and command sets differ.
Package TSSOP-16 TSSOP-28 Package footprint and pin count affect PCB layout and whether a drop-in replacement is possible.
Operating temperature range -40 °C to +105 °C -40 °C to +85 °C Temperature range determines suitability for harsh or industrial environments.
Input type Single-ended or differential Differential Differential-only inputs improve common-mode rejection but require different sensor wiring than single-ended inputs.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1246IPW ADS1282HIPW
Supplier - Rochester Electronics, LLC,Texas Instruments
Part Status Active Active
Number of Bits 24 -
Sampling Rate(Per Second) 2k -
Number of Inputs 1 -
Input Type Differential, Single Ended -
Data Interface SPI -
Configuration MUX-PGA-ADC -
Number of A/D Converters 1 -
Architecture Sigma-Delta -
Reference Type External, Internal -
Voltage - Supply, Analog 2.7V ~ 5.25V -
Voltage - Supply, Digital 2.7V ~ 5.25V -
Features PGA, Temperature Sensor -
Operating Temperature -40°C ~ 105°C -

Frequently asked questions

What are the primary differences between the ADS1246IPW and ADS1282HIPW?

The ADS1246IPW is a 24-bit, 2-kSPS delta-sigma ADC with a single differential input and integrated PGA, housed in a 20-pin TSSOP. The ADS1282HIPW is a 31-bit, 4-kSPS delta-sigma ADC with dual differential inputs, integrated PGA, and a high-resolution architecture, housed in a 28-pin TSSOP. The ADS1282HIPW targets high-resolution seismic and energy exploration applications, while the ADS1246IPW targets general-purpose precision sensor measurement.

Are the ADS1246IPW and ADS1282HIPW pin-compatible?

No. The ADS1246IPW uses a 20-pin TSSOP (PW) package, while the ADS1282HIPW uses a 28-pin TSSOP (PW) package. The pin counts and pin functions differ, so they are not drop-in replacements and require different PCB land patterns.

What are the resolution and data rate specifications of each device?

The ADS1246IPW provides 24-bit resolution with programmable data rates up to 2 kSPS. The ADS1282HIPW provides 31-bit resolution with programmable data rates up to 4 kSPS. The ADS1282HIPW offers higher resolution and a faster maximum output rate than the ADS1246IPW.

How do the input configurations of the ADS1246IPW and ADS1282HIPW differ?

The ADS1246IPW has a single differential input channel with an integrated PGA. The ADS1282HIPW provides two differential input channels with an integrated PGA, allowing multiplexed measurement of two sensor signals without external switching.

Do both devices include an integrated programmable gain amplifier (PGA)?

Yes. Both the ADS1246IPW and ADS1282HIPW integrate a programmable gain amplifier. The PGA gain settings and ranges should be verified against the respective manufacturer datasheets, as the available gain options and input voltage ranges differ between the two devices.

What are the typical target applications for the ADS1246IPW versus the ADS1282HIPW?

The ADS1246IPW is typically used in general-purpose precision sensor measurement, industrial process control, and portable instrumentation. The ADS1282HIPW is designed for high-resolution seismic data acquisition, energy exploration, and precision geophysical measurement where 31-bit resolution and dual input channels are required.

Can the ADS1246IPW be used as a substitute for the ADS1282HIPW in an existing design?

No, not as a direct substitute. The devices differ in package pin count (20 vs 28 pins), resolution (24-bit vs 31-bit), maximum data rate (2 kSPS vs 4 kSPS), and input channel count (single vs dual differential). Any substitution requires a full design review against the manufacturer datasheets, including PCB layout, timing, and system accuracy requirements.