ADS1252U/2K5 vs ADS1286UL

ADS1252U/2K5とADS1286ULの詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS1252U/2K5 and ADS1286UL are both 24-bit delta-sigma ADCs, but they differ fundamentally in resolution architecture, interface, sampling rate, and package, so the ADS1286UL cannot serve as a direct drop-in substitute for the ADS1252U/2K5 without a full board and firmware redesign.

Different output interface Different sampling rate Different package type Different input configuration

Parts at a glance

Part A

ADS1252U/2K5

STマイクロエレクトロニクス

Lifecycle
Active
Stock
6702 個数
Package
SOIC-8
Series
データ取得 - アナログ/デジタルコンバータ (ADC)
Part B

ADS1286UL

STマイクロエレクトロニクス

Lifecycle
Active
Stock
9742 個数
Package
SOIC-8
Series
データ取得 - アナログ/デジタルコンバータ (ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1252U/2K5 ADS1286UL Why it matters
Resolution (bits) 24 12 Resolution determines the smallest signal change the ADC can distinguish; a 24-bit device offers far finer measurement granularity than a 12-bit device.
Architecture Delta-Sigma SAR Delta-sigma converters excel at high-resolution low-frequency signals, while SAR converters offer faster sampling with lower latency; architecture drives the application fit.
Sampling Rate (max) 41 kSPS 20 kSPS Maximum sample rate limits the bandwidth of signals that can be digitized and affects throughput in multiplexed or fast-changing measurement systems.
Input Type Differential Differential Differential inputs reject common-mode noise and improve accuracy in electrically noisy environments; both parts share this beneficial input configuration.
Interface SPI (serial) SPI (serial) A serial SPI interface reduces pin count and simplifies isolation; matching interfaces eases drop-in replacement at the digital side.
Supply Voltage 5 V (single supply) 5 V (single supply) Supply voltage compatibility determines whether the part can be used in the same power rail without level shifting or additional regulation.
Package SOIC-8 SOIC-8 Package footprint compatibility is essential for physical substitutability on an existing PCB layout.
Operating Temperature Range -40 to +85 °C -40 to +85 °C The temperature range defines the environments in which the device is guaranteed to meet specifications; matching ranges support equivalent application use.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1252U/2K5 ADS1286UL
Supplier - Rochester Electronics, LLC,Texas Instruments
Part Status Active Obsolete
Number of Bits 24 12
Sampling Rate(Per Second) 40k 20k
Number of Inputs 1 1
Input Type Differential Differential
Data Interface SPI SPI
Configuration ADC S/H-ADC
Ratio - S / H: ADC - 1:1
Number of A/D Converters 1 1
Architecture Sigma-Delta SAR
Reference Type External External
Voltage - Supply, Analog 5V 5V
Voltage - Supply, Digital 5V 5V
Operating Temperature -40°C ~ 85°C 0°C ~ 70°C

Frequently asked questions

What are the key architectural differences between the ADS1252U/2K5 and the ADS1286UL?

The ADS1252U/2K5 is a 24-bit delta-sigma analog-to-digital converter with a fixed data rate of 41.7 kSPS and a serial interface, supplied in an SOIC-8 package. The ADS1286UL is a 12-bit successive-approximation register (SAR) ADC with a maximum sampling rate of 20 kSPS, an SPI-compatible interface, and is supplied in a TSSOP-8 package. They differ in resolution, conversion architecture, and maximum throughput.

Can the ADS1252U/2K5 and ADS1286UL be used as direct substitutes for each other?

No. The two devices differ in resolution (24-bit vs 12-bit), conversion architecture (delta-sigma vs SAR), maximum data rate (41.7 kSPS vs 20 kSPS), package (SOIC-8 vs TSSOP-8), and pin functions. A direct drop-in replacement is not possible without redesign and validation against the respective datasheets.

What are the supply voltage requirements for each device?

The ADS1252U/2K5 operates from a single 5 V analog supply (with a separate digital supply pin) per its datasheet. The ADS1286UL operates from a single 5 V supply. Designers should confirm exact supply ranges and decoupling requirements from the respective manufacturer datasheets before layout.

How do the interface and data output formats differ between the ADS1252U/2K5 and ADS1286UL?

The ADS1252U/2K5 provides a serial output with a fixed 41.7 kSPS conversion rate and requires an external clock; data is output in a two's complement format. The ADS1286UL uses an SPI-compatible serial interface with a chip-select line and outputs 12-bit results. The host microcontroller firmware must be adapted to each protocol.

Which device is better suited for high-resolution, low-frequency measurement applications?

The ADS1252U/2K5, with its 24-bit delta-sigma architecture, is intended for high-resolution measurements of low-frequency signals. The ADS1286UL, being a 12-bit SAR converter, is better suited to lower-resolution, moderate-speed applications. Selection should be based on required resolution, noise performance, and throughput as specified in the datasheets.

Are the packages of the ADS1252U/2K5 and ADS1286UL footprint-compatible?

No. The ADS1252U/2K5 is offered in an SOIC-8 package, while the ADS1286UL is offered in a TSSOP-8 package. The package body dimensions and lead pitch differ, so the PCB land patterns are not interchangeable.

What are the operating temperature ranges for these converters?

Both the ADS1252U/2K5 and ADS1286UL are specified for industrial temperature operation. Designers should verify the exact temperature grade and specified limits in the respective manufacturer datasheets, as these parameters must not be assumed without confirmation.