ADS1246IPWR vs ADS1281IPW

ADS1246IPWRとADS1281IPWの詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS1281IPW and ADS1246IPWR are not drop-in replacements for one another. The ADS1281IPW is a high-resolution 31-bit delta-sigma ADC with a single channel and a serial SPI interface in a TSSOP-28 package, while the ADS1246IPWR is a 24-bit delta-sigma ADC with a single channel and a serial SPI interface in a TSSOP-16 package. Their differing resolution, package footprint, and analog input architecture prevent direct substitution without a full redesign of the surrounding circuitry and PCB layout.

Different resolution Different package footprint Different analog input architecture Different reference and supply requirements

Parts at a glance

Part A

ADS1246IPWR

STマイクロエレクトロニクス

Lifecycle
Active
Stock
2336 個数
Package
TSSOP-16
Series
データ取得 - アナログ/デジタルコンバータ (ADC)
Part B

ADS1281IPW

STマイクロエレクトロニクス

Lifecycle
Active
Stock
4383 個数
Package
TSSOP-24
Series
データ取得 - アナログ/デジタルコンバータ (ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1281IPW ADS1246IPWR Why it matters
Resolution (bits) 31 24 Higher resolution provides finer measurement granularity; the ADS1281 offers 7 extra bits, enabling much lower noise floors for precision seismic or energy-exploration applications.
Number of input channels 1 (differential) 1 (differential) Both are single-channel differential ADCs, so channel count is not a differentiator for substitutability.
Maximum sample rate 4 kSPS 2 kSPS Sample rate determines the bandwidth of signals that can be captured; the ADS1281 supports twice the throughput, which matters for higher-frequency sensor data.
Interface type SPI (serial) SPI (serial) Both use a standard SPI interface, so host microcontroller compatibility is preserved across the two parts.
Supply voltage (analog) 5 V (analog), 3.3 V (digital) 2.7 V to 5.25 V (single supply) Supply requirements affect board-level power design; the ADS1246 offers a wider single-supply range while the ADS1281 uses a split analog/digital arrangement.
Package TSSOP-28 TSSOP-16 Different package footprints and pin counts mean the two parts are not drop-in PCB replacements and require layout changes.
Operating temperature range -40 °C to +85 °C -40 °C to +105 °C The wider temperature range of the ADS1246 suits harsher industrial environments, while the ADS1281 targets standard industrial conditions.
Integrated PGA No Yes (1 to 128 gain) An integrated PGA allows direct connection of low-level sensors without external amplification, simplifying the signal chain for the ADS1246.
Typical application focus Seismic and energy exploration, high-resolution instrumentation Precision sensor measurement, industrial process control The intended application domains differ, so functional substitutability depends on whether the design needs ultra-high resolution (ADS1281) or integrated gain and wider supply flexibility (ADS1246).

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1246IPWR ADS1281IPW
Part Status Active Active
Number of Bits 24 31
Sampling Rate(Per Second) 2k 4k
Number of Inputs 1 1
Input Type Differential, Single Ended Differential, Single Ended
Data Interface SPI SPI
Configuration MUX-PGA-ADC ADC
Number of A/D Converters 1 1
Architecture Sigma-Delta Sigma-Delta
Reference Type External External
Voltage - Supply, Analog 2.7V ~ 5.25V 5V
Voltage - Supply, Digital 2.7V ~ 5.25V 1.65V ~ 3.6V
Features PGA, Temperature Sensor -
Operating Temperature -40°C ~ 105°C -40°C ~ 85°C

Frequently asked questions

What are the primary differences between the ADS1281IPW and ADS1246IPWR?

The ADS1281IPW is a 31-bit, single-channel delta-sigma ADC with a maximum data rate of 4 kSPS, housed in a 24-pin TSSOP package, designed primarily for seismic and high-resolution energy exploration applications. The ADS1246IPWR is a 24-bit, single-channel delta-sigma ADC with a maximum data rate of 2 kSPS, housed in a 20-pin TSSOP package, designed for precision sensor measurement in industrial process control. Key differences include resolution (31-bit vs 24-bit), package pin count (24 vs 20), and maximum output data rate (4 kSPS vs 2 kSPS).

Are the ADS1281IPW and ADS1246IPWR pin-to-pin or package compatible?

No. The ADS1281IPW uses a 24-pin TSSOP (PW) package, while the ADS1246IPWR uses a 20-pin TSSOP (PW) package. The different pin counts and pin functions mean they are not drop-in replacements and require different PCB land patterns.

What are the maximum output data rates of the ADS1281IPW and ADS1246IPWR?

The ADS1281IPW supports a maximum data rate of 4 kSPS. The ADS1246IPWR supports a maximum data rate of 2 kSPS. Both are delta-sigma ADCs, but the ADS1281IPW is optimized for higher-speed, high-resolution seismic signal acquisition.

What resolution does each ADC provide?

The ADS1281IPW is a 31-bit delta-sigma ADC. The ADS1246IPWR is a 24-bit delta-sigma ADC. The higher bit depth of the ADS1281IPW supports very high dynamic range measurements, while the ADS1246IPWR targets general precision sensor measurement.

What are the typical target applications for the ADS1281IPW versus the ADS1246IPWR?

The ADS1281IPW is intended for seismic data acquisition, energy exploration, and high-resolution instrumentation requiring low noise and high dynamic range. The ADS1246IPWR is intended for industrial process control, precision sensor measurement, and portable instrumentation where a 24-bit ADC with integrated features is sufficient.

Do both devices support the same supply voltage range?

Both devices are specified for analog supply voltages in the 5 V class and digital supplies in the 1.8 V to 3.3 V range, but the exact recommended operating conditions, reference requirements, and internal PGA configurations differ. Designers must consult the respective manufacturer datasheets for verified supply, reference, and input range specifications before substitution.

Can the ADS1246IPWR be used as a substitute for the ADS1281IPW in an existing design?

No, not as a direct substitute. The devices differ in resolution (24-bit vs 31-bit), maximum data rate (2 kSPS vs 4 kSPS), package pin count (20 vs 24 pins), and target application requirements. Any substitution requires a full review of electrical specifications, package footprint, and system-level performance against the original design requirements.