ADS1281IPW vs ADS1271IPWG4

ADS1281IPWとADS1271IPWG4の詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The ADS1281IPW and ADS1271IPWG4 are both 24-bit delta-sigma ADCs in a TSSOP-24 package, but they differ in resolution architecture, data rate, and interface configuration. The ADS1281IPW offers higher resolution and lower noise for seismic and precision applications, while the ADS1271IPWG4 provides a wider selectable data rate range and flexible SPI-compatible interface. Designers should validate clock requirements, digital interface timing, and reference configuration before substituting one for the other in an existing design.

Resolution and Architecture Validation required
Data Rate Validation required
Package Type High match
Digital Interface Validation required

Parts at a glance

Part A

ADS1281IPW

STマイクロエレクトロニクス

Lifecycle
Active
Stock
4383 個数
Package
TSSOP-24
Series
データ取得 - アナログ/デジタルコンバータ (ADC)
Part B

ADS1271IPWG4

STマイクロエレクトロニクス

Lifecycle
Active
Stock
3928 個数
Package
TSSOP-16
Series
データ取得 - アナログ/デジタルコンバータ (ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1281IPW ADS1271IPWG4 Why it matters
Resolution (bits) 31 24 Higher resolution provides finer measurement granularity and lower quantization noise, which is critical for precision sensor and seismic applications.
Maximum Sample Rate (SPS) 4000 105000 Sample rate determines the maximum signal bandwidth the ADC can capture; the ADS1271 supports much faster data acquisition.
Architecture Delta-Sigma Delta-Sigma Both use delta-sigma conversion, but the ADS1281 is optimized for ultra-high resolution while the ADS1271 targets wider bandwidth.
Input Type Differential Differential Differential inputs improve common-mode noise rejection, important for low-level signal measurement in noisy environments.
Supply Voltage (Analog) 5 V 5 V Analog supply voltage must match the system rail; both operate from a 5 V analog supply, easing board-level substitution.
Interface SPI SPI A compatible serial interface simplifies firmware and host processor integration when swapping parts.
Package TSSOP-24 TSSOP-24 Matching package and pin count allows drop-in PCB compatibility without layout changes.
Operating Temperature Range -40 to +85 °C -40 to +105 °C Wider temperature range affects suitability for industrial and harsh-environment deployments.
Power Consumption (typical) 12 mW 70 mW Lower power dissipation reduces thermal load and extends battery life in portable or energy-sensitive systems.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1281IPW ADS1271IPWG4
Supplier - Texas Instruments
Part Status Active Discontinued at Digi-Key
Number of Bits 31 24
Sampling Rate(Per Second) 4k 105k
Number of Inputs 1 1
Input Type Differential, Single Ended Differential
Data Interface SPI SPI
Configuration ADC ADC
Number of A/D Converters 1 1
Architecture Sigma-Delta Sigma-Delta
Reference Type External External
Voltage - Supply, Analog 5V 5V
Voltage - Supply, Digital 1.65V ~ 3.6V 1.65V ~ 3.6V
Operating Temperature -40°C ~ 85°C -40°C ~ 105°C

Frequently asked questions

What are the key architectural differences between the ADS1281IPW and ADS1271IPWG4?

The ADS1281IPW is a single-channel, 31-bit delta-sigma ADC designed for high-resolution seismic and energy exploration applications, featuring a programmable gain amplifier and selectable digital filter options. The ADS1271IPWG4 is a 24-bit, single-channel delta-sigma ADC optimized for wide-bandwidth industrial measurement with a fixed 105 kSPS data rate and a choice of three filter modes (high-speed, high-resolution, low-power). The ADS1281 offers higher resolution (31-bit) and lower noise for low-frequency signals, while the ADS1271 provides wider signal bandwidth and faster throughput.

Are the ADS1281IPW and ADS1271IPWG4 pin-compatible?

No. Both devices are offered in a 24-pin TSSOP package (PW suffix), but their pin functions and internal architectures differ. The ADS1281IPW includes dedicated pins for a programmable gain amplifier input, reference buffers, and synchronization, while the ADS1271IPWG4 has a different pin assignment for its clock, filter mode selection, and data-ready signaling. A direct PCB drop-in replacement is not supported without layout and schematic changes.

How do the data output rates of the ADS1281IPW and ADS1271IPWG4 compare?

The ADS1281IPW supports programmable output data rates from 250 SPS to 4 kSPS, depending on the selected digital filter and clock configuration, making it suitable for low-frequency, high-resolution measurements. The ADS1271IPWG4 provides a fixed 105 kSPS output data rate in high-speed mode, with lower rates available in high-resolution and low-power modes. The ADS1271 is therefore better suited for applications requiring wider bandwidth, while the ADS1281 targets precision low-frequency signal acquisition.

Which device offers better noise performance for low-frequency signal acquisition?

The ADS1281IPW is specified with very low input-referred noise and high resolution (31-bit) tailored for seismic and low-frequency precision measurement, typically achieving noise levels in the sub-microvolt range at low data rates. The ADS1271IPWG4, while a high-performance 24-bit converter, is optimized for wider bandwidth industrial applications and does not match the ADS1281's low-frequency noise floor. For low-frequency, high-resolution acquisition, the ADS1281IPW is the more appropriate choice.

What are the supply voltage and power consumption differences between the two ADCs?

The ADS1281IPW operates from an analog supply of 5 V (with a separate digital supply of 1.8 V to 3.3 V) and typically consumes approximately 12 mW in normal operation. The ADS1271IPWG4 operates from a 5 V analog supply and a 1.8 V to 3.3 V digital supply, with power consumption typically around 130 mW in high-speed mode and lower in low-power mode. The ADS1281 is significantly lower power, reflecting its low-frequency precision design target.

Can the ADS1271IPWG4 be used as a replacement for the ADS1281IPW in seismic applications?

No, not directly. The ADS1281IPW is specifically designed for seismic and energy exploration with 31-bit resolution, programmable gain, and low-frequency digital filter options optimized for geophone and hydrophone signals. The ADS1271IPWG4 offers 24-bit resolution and a fixed 105 kSPS rate with different filter characteristics, which may not meet the dynamic range and noise requirements of seismic acquisition. Replacement would require thorough validation against the application's resolution, noise, and filter requirements.

What digital filter options are available on each device?

The ADS1281IPW provides selectable digital filter options including a linear-phase finite impulse response (FIR) filter, a low-latency sinc filter, and a high-resolution filter, configurable via register settings to suit different low-frequency measurement needs. The ADS1271IPWG4 offers three fixed filter modes: high-speed, high-resolution, and low-power, selected via dedicated pins. The ADS1281's filter programmability provides greater flexibility for precision low-frequency applications, while the ADS1271's pin-selectable modes simplify configuration for industrial designs.

Which device is more suitable for wide-bandwidth industrial measurement?

The ADS1271IPWG4 is more suitable for wide-bandwidth industrial measurement. Its 105 kSPS data rate and high-speed filter mode support signal bandwidths up to approximately 50 kHz, making it appropriate for vibration, power monitoring, and industrial control applications. The ADS1281IPW, with a maximum 4 kSPS data rate, is intended for low-frequency precision measurements and does not provide the bandwidth required for wide-band industrial signal acquisition.