ADS124S06IPBS
STマイクロエレクトロニクス
- Lifecycle
- Active
- Stock
- 2820 個数
- Package
- TQFP-32
- Series
- データ取得 - アナログ/デジタルコンバータ (ADC)
ADS124S06IPBSとADS1292RIPBSRの詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。
Replacement verdict
The ADS1292RIPBSR and ADS124S06IPBS are not drop-in replacements for one another. The ADS1292RIPBSR is a dedicated two-channel biopotential front-end with integrated respiration impedance measurement, while the ADS124S06IPBS is a precision six-channel delta-sigma ADC for general sensor measurement. Their channel architecture, integrated functionality, and target application domains differ fundamentally, so substituting one for the other requires a complete redesign of the signal chain rather than a direct part swap.
STマイクロエレクトロニクス
STマイクロエレクトロニクス
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADS1292RIPBSR | ADS124S06IPBS | Why it matters |
|---|---|---|---|
| Resolution (bits) | 24 | 24 | Both are 24-bit delta-sigma converters, so nominal resolution is equivalent for precision measurement. |
| Number of input channels | 2 differential (2 ADC channels) | 6 single-ended / 3 differential (multiplexed) | Channel count determines how many signals can be measured; the ADS124S06 offers more inputs via an input multiplexer. |
| Primary application focus | Biopotential / ECG measurement (integrated respiration impedance) | General-purpose precision sensor measurement | The ADS1292R includes ECG-specific features (respiration impedance, lead-off detection) not present on the general-purpose ADS124S06. |
| Integrated PGA | Yes (gain 1 to 12) | Yes (gain 1 to 128) | PGA gain range affects the smallest signal that can be resolved; the ADS124S06 supports higher gains for low-level sensors. |
| Data rate (max SPS) | 8000 SPS | 4000 SPS | Maximum sample rate limits bandwidth; the ADS1292R supports higher throughput for fast biopotential signals. |
| Supply voltage | 2.7 V to 5.25 V (analog and digital) | 2.7 V to 5.25 V (analog), 1.65 V to 3.6 V (digital) | Supply requirements affect system power design and logic-level compatibility with the host controller. |
| Interface | SPI | SPI | Both use SPI, so the same host interface type can be reused, though register maps and commands differ. |
| Package | 32-pin TQFP (PBS) | 32-pin TQFP (PBS) | Identical package and pin count simplify PCB footprint reuse, but pin functions are not interchangeable. |
| Operating temperature range | -40 °C to +85 °C | -50 °C to +125 °C | The wider temperature range of the ADS124S06 suits harsher industrial environments. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADS124S06IPBS | ADS1292RIPBSR |
|---|---|---|
| Part Status | Active | Active |
| Number of Bits | 24 | 24 |
| Sampling Rate(Per Second) | 4k | - |
| Number of Inputs | 6 | - |
| Input Type | Single Ended | - |
| Data Interface | SPI | - |
| Configuration | MUX-PGA-ADC | - |
| Ratio - S / H: ADC | 0:1 | - |
| Number of A/D Converters | 1 | - |
| Architecture | Sigma-Delta | - |
| Reference Type | External, Internal | - |
| Voltage - Supply, Analog | 2.7V ~ 5.25V | 2.7V ~ 5.25V |
| Voltage - Supply, Digital | 2.7V ~ 3.6V | 1.7V ~ 3.6V |
| Features | PGA | - |
| Operating Temperature | -50°C ~ 125°C | - |
| Number of Channels | - | 2 |
| Power (Watts) | - | 740 µW |
| Mounting Type | - | Surface Mount |
The ADS1292RIPBSR is a 2-channel, 24-bit delta-sigma analog front-end (AFE) designed specifically for biopotential measurements such as ECG and respiration, integrating a respiration impedance measurement block. The ADS124S06IPBS is a 6-channel, 24-bit delta-sigma ADC intended for general-purpose precision sensor measurement, without a dedicated respiration or biopotential AFE. The ADS1292R integrates two simultaneous PGAs and a respiration modulator, while the ADS124S06 provides six single-ended or three differential inputs with a general-purpose PGA.
No. Both devices are offered in a TQFP-32 (PBS) package, but their pin functions and internal signal routing differ because the ADS1292R includes dedicated respiration and biopotential AFE pins, whereas the ADS124S06 exposes general-purpose ADC input and reference pins. A direct drop-in replacement is not supported; the PCB layout and pin assignments must be reviewed against each respective datasheet.
The ADS1292RIPBSR is the appropriate choice for ECG and respiration monitoring because it integrates a 2-channel biopotential AFE with a respiration impedance measurement block, internal oscillators, and right-leg drive circuitry tailored to those applications. The ADS124S06IPBS is a general-purpose precision ADC and does not include a dedicated respiration modulator or biopotential-specific front-end features.
The ADS1292RIPBSR provides 2 differential input channels for simultaneous biopotential acquisition. The ADS124S06IPBS provides 6 single-ended or 3 differential inputs, offering more general-purpose measurement channels but without the biopotential-specific signal chain of the ADS1292R.
Both devices use an SPI-compatible serial interface for register configuration and data readout, which is standard for this family of TI delta-sigma converters. However, the specific register maps, command sets, and data output formats differ between the ADS1292R and ADS124S06, so firmware and driver software are not interchangeable and must be developed per each device's datasheet.
Not as a direct substitute. The ADS124S06IPBS lacks the integrated respiration impedance measurement block, biopotential-specific PGA configuration, and right-leg drive features of the ADS1292RIPBSR. Substitution would require redesign of the analog front-end, revalidation of signal chain performance, and firmware changes, and should only be undertaken after review of both datasheets and application requirements.
Both are 24-bit delta-sigma converters. The ADS1292RIPBSR is optimized for biopotential signal bandwidths with programmable data rates suitable for ECG and respiration, while the ADS124S06IPBS offers programmable data rates for general-purpose precision sensing. Exact data rate ranges and filter settings should be confirmed from the respective manufacturer datasheets, as they differ between the two devices.