ADS127L01IPBSR
STマイクロエレクトロニクス
- Lifecycle
- Active
- Stock
- 3034 個数
- Package
- TQFP-32
- Series
- データ取得 - アナログ/デジタルコンバータ (ADC)
ADS127L01IPBSRとADS1294IPAGの詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。
Replacement verdict
The ADS1294IPAG and ADS127L01IPBSR are not drop-in replacements for one another. The ADS1294IPAG is a four-channel, 24-bit simultaneous-sampling biopotential front end with integrated programmable gain amplifiers and a delta-sigma architecture intended for ECG and EEG signal acquisition, while the ADS127L01IPBSR is a single-channel, 24-bit wide-bandwidth delta-sigma ADC optimized for high-speed precision data acquisition. Their channel count, analog front-end integration, package footprint, and target application domains differ fundamentally, so substituting one for the other requires a complete redesign of the signal chain rather than a direct board-level swap.
STマイクロエレクトロニクス
STマイクロエレクトロニクス
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADS1294IPAG | ADS127L01IPBSR | Why it matters |
|---|---|---|---|
| Number of ADC channels | 4 | 1 | Determines how many simultaneous signal inputs can be digitized; a 4-channel device cannot directly replace a single-channel device in multi-channel acquisition systems. |
| Resolution | 24 bit | 24 bit | Both provide 24-bit resolution, so dynamic range and precision class are comparable for high-accuracy measurement applications. |
| Maximum data rate (SPS) | 32 kSPS | 512 kSPS | The sample rate ceiling dictates the maximum signal bandwidth that can be captured; the ADS127L01 supports much higher throughput for wideband signals. |
| Input type / architecture | Delta-sigma with integrated PGA and ECG front end | Delta-sigma with wideband filter | The ADS1294 integrates biopotential-specific front-end features (PGA, RLD), while the ADS127L01 targets general wideband precision; functional substitutability depends on the application. |
| Supply voltage | 2.7 V to 5.25 V (analog), 1.65 V to 3.6 V (digital) | 2.7 V to 3.6 V (analog), 1.7 V to 3.6 V (digital) | Supply rails must match the host system; the ADS1294 tolerates a wider analog supply range, affecting board-level compatibility. |
| Interface | SPI | SPI | Both use SPI, so the digital host connection protocol is compatible, simplifying firmware reuse. |
| Package | 64-TQFP (PAG) | 32-TQFP (PBS) | Different footprints and pin counts mean the parts are not drop-in replacements; PCB layout must be redesigned. |
| Operating temperature range | -40 °C to +85 °C | -40 °C to +125 °C | The wider temperature range of the ADS127L01 suits harsher environments, while the ADS1294 is limited to standard industrial conditions. |
| Typical application focus | ECG / biopotential and medical instrumentation | Wideband precision data acquisition and industrial measurement | Target application domains differ significantly, so direct substitution requires verifying whether the specific signal chain requirements are met. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADS127L01IPBSR | ADS1294IPAG |
|---|---|---|
| Part Status | Active | Active |
| Number of Bits | 24 | 24 |
| Sampling Rate(Per Second) | 512k | - |
| Number of Inputs | 1 | - |
| Input Type | Differential | - |
| Data Interface | SPI | - |
| Configuration | ADC | - |
| Number of A/D Converters | 1 | - |
| Architecture | Sigma-Delta | - |
| Reference Type | External | - |
| Voltage - Supply, Analog | 2.7V ~ 3.6V | 2.7V ~ 5.5V |
| Voltage - Supply, Digital | 1.7V ~ 3.6V | 1.65V ~ 3.6V |
| Operating Temperature | -40°C ~ 125°C | - |
| Number of Channels | - | 4 |
| Power (Watts) | - | 10.1 mW |
| Mounting Type | - | Surface Mount |
The ADS1294IPAG is a 4-channel, 24-bit delta-sigma analog front-end (AFE) designed for biopotential measurements, integrating programmable gain amplifiers, an internal reference, and ECG/EEG-specific features. The ADS127L01IPBSR is a single-channel, 24-bit delta-sigma analog-to-digital converter optimized for wide-bandwidth, high-resolution industrial signal acquisition with a maximum data rate of 512 kSPS. The ADS1294IPAG targets multi-channel biopotential systems, while the ADS127L01IPBSR targets single-channel precision industrial measurement.
No. The ADS1294IPAG is supplied in a 64-pin TQFP package (PAG suffix), while the ADS127L01IPBSR is supplied in a 32-pin TQFP package (PBSR suffix). The two devices have different pin counts, pin functions, and PCB land patterns, so they are not pin-compatible and cannot be interchanged on the same footprint.
No. The ADS1294IPAG is a multi-channel biopotential AFE with integrated PGAs and ECG-specific functionality, whereas the ADS127L01IPBSR is a single-channel wide-bandwidth ADC. Their channel counts, input architectures, package footprints, and target applications differ, so direct substitution is not possible without a complete redesign of the signal chain and PCB.
The ADS1294IPAG supports programmable output data rates up to 32 kSPS per channel, which is sufficient for standard ECG and EEG bandwidths. The ADS127L01IPBSR supports a maximum data rate of 512 kSPS in wide-bandwidth mode, making it suitable for higher-frequency industrial signal acquisition. The ADS127L01IPBSR offers a substantially higher maximum sample rate than the ADS1294IPAG.
The ADS1294IPAG is intended for biopotential acquisition such as electrocardiogram (ECG), electroencephalogram (EEG), and electromyogram (EMG) systems, as well as patient monitoring and portable medical instrumentation. The ADS127L01IPBSR is intended for industrial precision measurement, including vibration analysis, power quality monitoring, test and measurement equipment, and other wide-bandwidth data acquisition systems.
The ADS1294IPAG integrates a programmable gain amplifier (PGA) per channel and includes an internal reference, supporting direct connection of small biopotential signals. The ADS127L01IPBSR does not include an integrated PGA; it is a standalone ADC that requires external signal conditioning and typically an external reference for full-scale definition. The integration level and analog front-end architecture therefore differ significantly between the two devices.
The ADS1294IPAG operates from an analog supply of 2.7 V to 5.25 V and a digital supply of 1.65 V to 3.6 V, with an additional unipolar or bipolar analog supply arrangement for biopotential inputs. The ADS127L01IPBSR operates from a 2.7 V to 3.6 V analog supply and a 1.7 V to 3.6 V digital supply. Designers should verify the exact supply rails and sequencing requirements against the respective manufacturer datasheets before layout.