AMC1300BDWVR vs AMC1301DWVR

AMC1300BDWVRとAMC1301DWVRの詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The AMC1301DWVR and AMC1300BDWVR are both isolated amplifiers in the same SOIC-8 (DWV) package with identical pinout and 5.0 kV reinforced isolation ratings, making them strong functional replacement candidates. The primary distinction is gain: the AMC1301DWVR provides a fixed gain of 8, while the AMC1300BDWVR provides a fixed gain of 1, so the replacement is only valid when the system's signal scaling is adjusted accordingly. Input offset and gain error specifications also differ slightly, so validation in the target application is recommended before committing to a drop-in substitution.

Package and Pinout High match
Isolation Rating High match
Fixed Gain Validation required
Input Offset and Gain Error Validation required

Parts at a glance

Part A

AMC1300BDWVR

STマイクロエレクトロニクス

Lifecycle
Active
Stock
1306 個数
Package
SOIC-8
Series
リニアアンプ - 特殊用途
Part B

AMC1301DWVR

STマイクロエレクトロニクス

Lifecycle
Active
Stock
6629 個数
Series
リニアアンプ - 計装用、オペアンプ、バッファアンプ

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AMC1301DWVR AMC1300BDWVR Why it matters
Input Voltage Range ±250 mV ±250 mV Defines the differential input span the isolated amplifier can accept; both match, so signal scaling is compatible.
Fixed Gain 8.2 V/V 8.2 V/V Gain determines output scaling relative to input; identical gain allows direct substitution without recalibration.
Isolation Rating (VISO) 5000 V RMS (reinforced) 5000 V RMS (reinforced) Isolation voltage is critical for safety and working voltage in high-voltage systems; matching ratings preserve safety margins.
Supply Voltage (High Side) 3.0 V to 5.5 V 3.0 V to 5.5 V Determines compatibility with the high-side supply rail; identical ranges allow the same power design.
Supply Voltage (Low Side) 3.0 V to 5.5 V 3.0 V to 5.5 V Low-side supply must match the controller/ADC logic level; identical ranges ensure interface compatibility.
Bandwidth 1 MHz (typical) 1 MHz (typical) Bandwidth affects response speed for current sensing loops; matching bandwidth preserves dynamic performance.
Input Offset Error ±0.2 mV (max) ±0.2 mV (max) Offset error impacts measurement accuracy at low currents; identical limits maintain accuracy specifications.
Operating Temperature Range -40 °C to +125 °C -40 °C to +125 °C Temperature range defines environmental robustness; matching ranges allow use in the same operating conditions.
Package 8-SOIC (DWV) 8-SOIC (DWV) Package footprint and pinout must match for drop-in replacement; identical packages ensure PCB compatibility.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AMC1300BDWVR AMC1301DWVR
Part Status Active Active
Type Isolation -
Applications Current Sensing, Power Management -
Mounting Type Surface Mount Surface Mount
Amplifier Type - Isolation
Number of Circuits - 1
Gain Bandwidth Product - 1 MHz
Current - Input Bias - 60 µA
Voltage - Input Offset - 50 µV
Supply Current - 5.9mA
Current - Output / Channel - 13 mA
Voltage - Supply Span(Min) - 3 V
Voltage - Supply Span(Max) - 5.5 V
Operating Temperature - -40°C ~ 125°C

Frequently asked questions

What are the key differences between the AMC1301DWVR and AMC1300BDWVR isolated amplifiers?

Both are Texas Instruments reinforced isolated amplifiers in a 5.85 mm × 7.5 mm SOIC-8 (DWV) package, but they differ in gain and input range. The AMC1301DWVR has a fixed gain of 8 V/V with a nominal input range of ±250 mV, while the AMC1300BDWVR has a fixed gain of 8.2 V/V with a nominal input range of ±250 mV. The AMC1301 is optimized for shunt-based current sensing with a ±50 mV to ±250 mV linear input range, whereas the AMC1300B offers a slightly higher gain and a wider specified input range of ±250 mV with improved offset and gain error specifications.

Are the AMC1301DWVR and AMC1300BDWVR pin-compatible?

Yes. Both devices are offered in the same 8-pin SOIC (DWV) package with identical pin functions: VDD1, INP, INN, GND1 on the input side and VDD2, OUTP, OUTN, GND2 on the output side. This allows a common PCB footprint, but the gain and accuracy differences must be evaluated before substituting one for the other in an existing design.

What isolation rating do the AMC1301DWVR and AMC1300BDWVR provide?

Both devices are reinforced isolated amplifiers rated for 5 kV RMS isolation per UL 1577 and provide a working voltage of 1.5 kV peak per VDE V 0884-11 (VDE 0884-11). They are suitable for isolated current and voltage sensing in motor drives, inverters, and industrial systems requiring reinforced isolation.

What is the gain and input voltage range of each device?

The AMC1301DWVR has a fixed gain of 8 V/V and a specified linear input range of ±250 mV (with ±50 mV to ±250 mV recommended for shunt sensing). The AMC1300BDWVR has a fixed gain of 8.2 V/V and a specified input range of ±250 mV. The slightly higher gain of the AMC1300B provides a marginally larger output swing for the same input, which must be accounted for in the downstream ADC scaling.

Which device offers better accuracy specifications?

The AMC1300BDWVR specifies tighter offset and gain error than the AMC1301DWVR. The AMC1300B has a maximum input offset error of ±0.3 mV and a maximum gain error of ±0.3%, while the AMC1301 specifies a maximum input offset error of ±1 mV and a maximum gain error of ±1%. For designs requiring higher DC accuracy, the AMC1300B is the preferred choice.

Can the AMC1301DWVR and AMC1300BDWVR be used interchangeably in a shunt-based current sensing design?

They are pin-compatible and share the same isolation rating, but they are not drop-in interchangeable without validation. The gain difference (8 V/V vs. 8.2 V/V) and the tighter accuracy of the AMC1300B change the output scaling and error budget. The downstream ADC or controller must be recalibrated, and the system error analysis must be re-evaluated before substitution.

What are the supply voltage and temperature range specifications for both devices?

Both the AMC1301DWVR and AMC1300BDWVR operate from a 3.0 V to 5.5 V supply on both the high-side (VDD1) and low-side (VDD2) domains, and both are specified over the industrial temperature range of −40 °C to +125 °C. This makes them suitable for harsh industrial environments such as motor control and power conversion.

Which device is better suited for high-precision motor drive current sensing?

The AMC1300BDWVR is generally preferred for high-precision current sensing because of its tighter offset and gain error specifications (±0.3 mV and ±0.3% maximum, respectively) compared with the AMC1301DWVR (±1 mV and ±1% maximum). Both provide reinforced isolation and are suitable for shunt-based phase current sensing, but the AMC1300B reduces the need for end-of-line calibration in precision drive designs.