AD637JQ vs AD637KDZ

AD637JQとAD637KDZの詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The AD637KDZ is a functionally compatible replacement candidate for the AD637JQ, sharing the same RMS-to-DC conversion topology, package footprint, and supply requirements. The primary distinction is the grade-level accuracy specification, which requires validation against the target application's error budget before substitution.

Function and Topology High match
Package Type High match
Accuracy Grade Validation required
Supply Voltage Range High match

Parts at a glance

Part A

AD637JQ

テキサス・インスツルメンツ

Lifecycle
Active
Stock
5643 個数
Package
CDIP-14
Series
PMIC - RMS-DCコンバータ
Part B

AD637KDZ

テキサス・インスツルメンツ

Lifecycle
Active
Stock
31 個数
Package
CDIP-14
Series
PMIC - RMS-DCコンバータ

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AD637JQ AD637KDZ Why it matters
Package / Mounting Type 14-Lead CERDIP (through-hole) 14-Lead CERDIP (through-hole) Package style determines board footprint and assembly method; both are CERDIP through-hole, so they are physically interchangeable.
Temperature Grade / Operating Range Commercial (0°C to +70°C) Industrial (-40°C to +85°C) The wider industrial temperature range of the KDZ allows use in harsher environments where the commercial-grade JQ may not be specified.
Accuracy / Total Error ±0.5% max (RMS error, typical grade) ±0.2% max (higher accuracy grade) Tighter accuracy directly affects measurement precision; the KDZ offers better guaranteed error for demanding RMS measurement applications.
Function True RMS-to-DC converter True RMS-to-DC converter Both perform the same core function (computing true RMS of an input signal), so they are functionally substitutable in the same circuit topology.
Supply Voltage ±3 V to ±18 V dual supply ±3 V to ±18 V dual supply Identical supply requirements mean the same power rails can be used without redesign.
Bandwidth 8 MHz (at 200 mV rms) 8 MHz (at 200 mV rms) Matching bandwidth ensures equivalent AC signal handling capability for high-frequency RMS measurements.
Input Voltage Range 0 to 7 V rms (with ±15 V supplies) 0 to 7 V rms (with ±15 V supplies) Same input range means both parts handle the same signal amplitudes without clipping or attenuation differences.
Grade / Screening Level J grade (standard commercial) K grade (precision/industrial) The K grade is a higher-precision, wider-temperature screened version, which is the primary differentiator affecting cost and suitability for precision or industrial use.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AD637JQ AD637KDZ
Part Status Active Active
Supply Current 2.2 mA 2.2 mA
Voltage - Supply ±3V ~ 18V ±3V ~ 18V
Mounting Type Through Hole Through Hole

Frequently asked questions

What are the primary differences between the AD637JQ and AD637KDZ?

The AD637JQ and AD637KDZ are both RMS-to-DC converters from Analog Devices, but they differ in grade and package. The AD637JQ is specified for a commercial temperature range of 0°C to 70°C and comes in a 14-lead CERDIP (Q) package. The AD637KDZ is specified for an industrial temperature range of -40°C to +85°C and is supplied in a 14-lead SOIC (D) package with a RoHS-compliant designation (Z).

Are the AD637JQ and AD637KDZ functionally interchangeable in an existing design?

Functionally, both devices perform true RMS-to-DC conversion with the same core specifications, including a 0.5% maximum total error and a 200 mV to 7 V RMS input range. However, they are not drop-in replacements because the AD637JQ uses a CERDIP package and the AD637KDZ uses an SOIC package, which have different footprints and PCB land patterns. The temperature grade difference must also be validated against the application's operating environment.

What is the specified accuracy of the AD637JQ and AD637KDZ?

Both the AD637JQ and AD637KDZ are specified with a maximum total error of 0.5% for a 200 mV to 7 V RMS input at 1 kHz. This accuracy specification applies to the true RMS computation and is a key parameter for precision measurement applications.

What is the operating temperature range for each device?

The AD637JQ is rated for the commercial temperature range of 0°C to 70°C. The AD637KDZ is rated for the industrial temperature range of -40°C to +85°C. The AD637KDZ is therefore better suited for applications requiring operation outside a controlled commercial environment.

What package types are used for the AD637JQ and AD637KDZ?

The AD637JQ is housed in a 14-lead CERDIP (ceramic dual in-line) package. The AD637KDZ is housed in a 14-lead SOIC (small outline integrated circuit) package. The package choice affects board layout, thermal behavior, and assembly process compatibility.

Do the AD637JQ and AD637KDZ support the same input voltage range?

Yes. Both devices are specified for an RMS input voltage range of 200 mV to 7 V RMS. This range is a core parameter of the AD637 series and applies to both the JQ and KDZ grades.

What is the maximum operating frequency for the AD637JQ and AD637KDZ?

Both the AD637JQ and AD637KDZ are specified for operation up to 8 MHz, with the accuracy specification of 0.5% maximum total error defined at 1 kHz. Higher-frequency performance should be evaluated against the datasheet's frequency response curves for the specific grade.

Is the AD637KDZ RoHS compliant while the AD637JQ is not?

The AD637KDZ carries the "Z" suffix in its part number, which denotes a RoHS-compliant, lead-free package per Analog Devices' ordering nomenclature. The AD637JQ, with the "Q" suffix indicating a CERDIP package, is not designated as RoHS compliant in the same manner. Designers should confirm compliance status against the current manufacturer datasheet and ordering guide for the specific lot.