AD637JQ vs AD637SQ/883B

AD637JQとAD637SQ/883Bの詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The AD637JQ and AD637SQ/883B are functionally equivalent true RMS-to-DC converters sharing the same core architecture, pinout, and transfer function, making the AD637JQ a viable functional substitute for the AD637SQ/883B in applications where the extended temperature range and military screening of the SQ/883B grade are not mandatory. Designers should validate operation at the temperature extremes of the target application, since the JQ grade offers a narrower guaranteed operating temperature range than the SQ/883B grade.

Function and Transfer Function High match
Package and Pinout High match
Operating Temperature Range Validation required
Screening and Qualification Grade Validation required

Parts at a glance

Part A

AD637JQ

テキサス・インスツルメンツ

Lifecycle
Active
Stock
5643 個数
Package
CDIP-14
Series
PMIC - RMS-DCコンバータ
Part B

AD637SQ/883B

テキサス・インスツルメンツ

Lifecycle
Active
Stock
3458 個数
Package
CDIP-14
Series
PMIC - RMS-DCコンバータ

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AD637JQ AD637SQ/883B Why it matters
Temperature Range (Operating) 0°C to +70°C -55°C to +125°C The military-grade version supports a much wider operating temperature range, making it suitable for harsh environments where the commercial grade would fail.
Grade / Screening Commercial (J Grade) Military / QML Class V (883B) The 883B screening guarantees compliance with MIL-STD-883 reliability testing, which is required for defense and aerospace applications.
Package / Case 14-Lead CERDIP (Q) 14-Lead CERDIP (Q) Both use the same hermetic CERDIP package, ensuring physical and footprint compatibility for drop-in replacement.
Accuracy (RMS Conversion) 0.5% max error (typical grade) 0.5% max error (typical grade) Both grades share the same core RMS-to-DC conversion accuracy specification, so measurement precision is equivalent.
Supply Voltage ±3 V to ±18 V ±3 V to ±18 V Identical dual-supply range means both parts can be used in the same circuit without power rail redesign.
Bandwidth 8 MHz (at 200 mV rms) 8 MHz (at 200 mV rms) Matching bandwidth ensures the same AC signal handling capability for RMS measurement applications.
Input Voltage Range 0 to 7 V rms (with ±15 V supplies) 0 to 7 V rms (with ±15 V supplies) Equivalent input range confirms both devices handle the same signal amplitudes without clipping.
Qualification Standard Standard commercial MIL-STD-883 Method 5004/5005 The 883B part is fully qualified to military standards, which is critical for mission-critical systems requiring documented reliability.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AD637JQ AD637SQ/883B
Part Status Active Active
Supply Current 2.2 mA 2.2 mA
Voltage - Supply ±3V ~ 18V ±3V ~ 18V
Mounting Type Through Hole Through Hole

Frequently asked questions

What are the primary differences between the AD637JQ and AD637SQ/883B?

The AD637JQ is a commercial-grade RMS-to-DC converter in a 14-lead CERDIP package specified for 0°C to 70°C operation, while the AD637SQ/883B is the same core device screened to MIL-STD-883B requirements and specified over the -55°C to +125°C military temperature range. The /883B variant includes additional lot acceptance and screening testing per the 883B standard.

Are the AD637JQ and AD637SQ/883B functionally interchangeable in a circuit?

Yes, both devices share the same AD637 RMS-to-DC converter die and the same 14-lead CERDIP pinout, so the functional block diagram and external component connections are identical. Interchangeability in a specific design still depends on validating the temperature range, screening level, and any derating requirements against the application.

What temperature ranges do the AD637JQ and AD637SQ/883B support?

The AD637JQ is specified for commercial operation from 0°C to 70°C. The AD637SQ/883B is specified for the military temperature range of -55°C to +125°C, with parameters guaranteed over that extended range per the datasheet.

What does the /883B suffix indicate on the AD637SQ/883B?

The /883B suffix indicates the device has been processed and screened in accordance with MIL-STD-883, Method 5004 (Class B) requirements, including lot acceptance testing, burn-in, and other reliability screening steps. This differs from the AD637JQ, which is a standard commercial-grade part without MIL-STD-883B screening.

Do both parts use the same package and pinout?

Yes, both the AD637JQ and AD637SQ/883B are supplied in a 14-lead CERDIP (ceramic dual in-line) package with the same pin assignments, including the RMS input, output, denominator input, and filter/buffer connections. This common package and pinout supports drop-in replacement when temperature and screening requirements permit.

Which part should be selected for a military or high-reliability application?

The AD637SQ/883B should be selected for military or high-reliability applications because it is screened to MIL-STD-883B and specified over the -55°C to +125°C range. The AD637JQ, being a commercial 0°C to 70°C part without 883B screening, is not intended for those environments.

Are the accuracy and transfer specifications the same for both grades?

Both devices are AD637 true RMS-to-DC converters and share the same core transfer function and typical accuracy characteristics as documented in the AD637 datasheet. However, guaranteed limits should be taken from the respective grade's datasheet tables, since the AD637SQ/883B guarantees parameters over the full military temperature range while the AD637JQ guarantees them only over 0°C to 70°C.

Can the AD637JQ be used as a substitute for the AD637SQ/883B in an existing military design?

No, the AD637JQ should not be substituted for the AD637SQ/883B in a military design, because it lacks MIL-STD-883B screening and is only specified from 0°C to 70°C, which does not cover the -55°C to +125°C military range. Substitution would require revalidation of temperature performance and reliability screening against the application requirements.