ADM242AR
テキサス・インスツルメンツ
- Lifecycle
- Active
- Stock
- 6746 個数
- Package
- SOIC-18
- Series
- インターフェース - ドライバ、レシーバ、トランシーバ
ADM242ARとADM241LJRの詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。
Replacement verdict
The ADM241LJR is a functionally compatible candidate for the ADM242AR, sharing the same RS-232 transceiver function, dual driver/receiver channel count, and PDIP-24 package footprint. The primary distinction is the operating temperature range, where the ADM241LJR is specified for the commercial 0°C to 70°C range versus the industrial −40°C to +85°C range of the ADM242AR, so validation is required for industrial-temperature applications.
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADM242AR | ADM241LJR | Why it matters |
|---|---|---|---|
| Number of Drivers/Receivers | 2/2 | 4/0 | Defines the interface direction and channel count; a 2/2 transceiver cannot directly replace a 4/0 driver-only device in a given signal path. |
| Data Rate | 200 kbps | 120 kbps | Maximum supported signaling speed; the lower-rated part may not meet timing requirements of a system designed for the faster device. |
| Receiver Input Impedance | 3 kΩ to 7 kΩ | Not applicable (no receivers) | RS-232 receivers must present the standard 3–7 kΩ load; a driver-only device lacks receivers entirely, changing bus loading behavior. |
| Number of Charge Pump Capacitors | 4 (external) | 4 (external) | External charge-pump capacitors set the on-chip voltage generation; both require the same count, easing board-level substitution of the power section. |
| Operating Supply Voltage | 5 V | 5 V | Both operate from a single 5 V rail, so the power supply architecture is compatible between the two parts. |
| Shutdown / Enable Feature | Yes (active-low shutdown) | Yes (active-low shutdown) | Shutdown capability allows power savings; matching behavior means firmware and control-line logic remain compatible. |
| Package | 20-lead SOIC (wide) | 20-lead SOIC (wide) | Identical package and pin count allow the same PCB footprint, though pin functions differ due to driver/receiver configuration. |
| Operating Temperature Range | -40 °C to +85 °C | 0 °C to +70 °C | The wider industrial range of the ADM242AR supports harsher environments; the commercial-range part may not be suitable for extended-temperature applications. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADM242AR | ADM241LJR |
|---|---|---|
| Supplier | - | Analog Devices Inc.,Rochester Electronics, LLC |
| Part Status | Obsolete | Obsolete |
| Type | Transceiver | Transceiver |
| Protocol | RS232 | RS232 |
| Number of Drivers/Receivers | 2/2 | 4/5 |
| Duplex | Full | Full |
| Receiver Hysteresis | 400 mV | 650 mV |
| Data Rate | 200kbps | 120Kbps |
| Voltage - Supply | 4.5V ~ 5.5V | 4.75V ~ 5.25V |
| Operating Temperature | -40°C ~ 85°C | 0°C ~ 70°C |
| Mounting Type | Surface Mount | Surface Mount |
The ADM242AR is a dual-channel RS-232 line driver/receiver in a 20-lead SOIC package, while the ADM241LJR is a single-channel RS-232 transceiver in a 24-lead SOIC package. The ADM242AR integrates two drivers and two receivers, whereas the ADM241LJR integrates one driver and one receiver. Both operate from a single +5 V supply and include on-chip charge pump circuitry.
No. The ADM242AR uses a 20-lead SOIC package and the ADM241LJR uses a 24-lead SOIC package, so they have different pin counts and pinouts. They are not direct drop-in replacements for each other.
Both devices operate from a single +5 V supply. On-chip charge pump converters generate the required RS-232 voltage levels from this single supply.
The ADM242AR provides two RS-232 drivers and two RS-232 receivers. The ADM241LJR provides one RS-232 driver and one RS-232 receiver.
Yes. Both the ADM242AR and ADM241LJR include a shutdown mode that reduces power consumption when the RS-232 interface is inactive. The shutdown feature is controlled via a dedicated logic input pin.
Both devices are specified for RS-232 data rates up to 120 kbps, which is sufficient for standard RS-232 communication requirements.
No. Both devices are specified for +5 V single-supply operation. They are not rated for 3.3 V or other low-voltage supply rails. For 3 V RS-232 applications, a different device family should be selected.
Both devices are specified for the commercial temperature range of 0°C to +70°C. They are not rated for industrial or extended temperature operation.