ADS1210U vs ADS1252UG4

ADS1210UとADS1252UG4の詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS1210U and ADS1252UG4 are both 24-bit delta-sigma analog-to-digital converters, but they differ fundamentally in resolution architecture, interface protocol, package footprint, and reference configuration, so the ADS1252UG4 cannot serve as a direct drop-in substitute for the ADS1210U without redesign of the interface, layout, and external circuitry.

Different interface protocol Different package footprint Different reference configuration Different data rate capability

Parts at a glance

Part A

ADS1210U

STマイクロエレクトロニクス

Lifecycle
Active
Stock
5384 個数
Package
SOIC-8
Series
データ取得 - アナログ/デジタルコンバータ (ADC)
Part B

ADS1252UG4

STマイクロエレクトロニクス

Lifecycle
Active
Stock
6755 個数
Package
SOIC-8
Series
データ取得 - アナログ/デジタルコンバータ (ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1210U ADS1252UG4 Why it matters
Resolution (bits) 24 24 Both are 24-bit delta-sigma ADCs, so resolution alone does not distinguish them for substitutability.
Number of input channels 1 (differential) 1 (differential) Both provide a single differential input, so channel count is equivalent for single-sensor applications.
Maximum data rate (SPS) 10k 41k The ADS1252UG4 supports a much higher output rate, which matters for higher-bandwidth or faster-sampling applications.
Interface type SPI (serial) SPI (serial) Both use a serial SPI-compatible interface, simplifying drop-in replacement at the digital interface level.
Supply voltage (analog) 5 V 5 V Matching analog supply simplifies power-rail design when substituting one part for the other.
Package / mounting 18-SOIC (surface mount) 8-SOIC (surface mount) Different package footprints and pin counts mean the parts are not drop-in compatible on the same PCB layout.
Input type Differential Differential Both accept differential inputs, which is important for rejecting common-mode noise in precision measurement.
Operating temperature range -40°C to +85°C -40°C to +85°C Identical industrial temperature ranges mean both suit the same environmental conditions.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1210U ADS1252UG4
Part Status Last Time Buy Discontinued at Digi-Key
Number of Bits 24 24
Sampling Rate(Per Second) 16k 40k
Number of Inputs 1 1
Input Type Differential Differential
Data Interface SPI SPI
Configuration PGA-ADC ADC
Number of A/D Converters 1 1
Architecture Sigma-Delta Sigma-Delta
Reference Type External, Internal External
Voltage - Supply, Analog 5V 5V
Voltage - Supply, Digital 5V 5V
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C
Features PGA -

Frequently asked questions

What are the key architectural differences between the ADS1210U and ADS1252UG4?

The ADS1210U is a 24-bit delta-sigma ADC with a programmable gain amplifier (PGA) and a flexible input multiplexer, supporting differential inputs and a serial interface. The ADS1252UG4 is a 24-bit delta-sigma ADC with a fixed-gain, high-speed modulator and a simpler serial interface, optimized for high-speed data acquisition without an integrated PGA or input multiplexer.

Do the ADS1210U and ADS1252UG4 have the same package and pinout?

No. The ADS1210U is offered in a 24-pin SOIC (DW) package, while the ADS1252UG4 is offered in a 16-pin SOIC (DW) package. The pin counts and pin functions differ, so they are not pin-compatible and cannot be dropped into the same PCB footprint.

How do the maximum data rates of the ADS1210U and ADS1252UG4 compare?

The ADS1210U supports programmable output data rates up to approximately 15.6 kSPS depending on gain and mode settings. The ADS1252UG4 supports a fixed output data rate of up to 41 kSPS, making it better suited for higher-speed acquisition applications.

Can the ADS1210U and ADS1252UG4 operate from the same supply voltage?

Both devices operate from a single 5 V analog supply. However, the ADS1210U also requires a digital supply that can range from 2.7 V to 5.25 V, while the ADS1252UG4 operates with a single 5 V supply for both analog and digital domains. Designers should verify supply rail requirements against the respective datasheets.

Which device offers an integrated programmable gain amplifier?

Only the ADS1210U includes an integrated programmable gain amplifier (PGA) with selectable gains of 1, 2, 4, 8, and 16. The ADS1252UG4 does not include a PGA; its input range is fixed, so external signal conditioning is required for low-level signals.

Are the ADS1210U and ADS1252UG4 interchangeable in an existing design?

No. Differences in package pinout, data rate, PGA availability, input multiplexing, and digital interface timing prevent direct interchangeability. Any substitution requires a full review of the schematic, PCB layout, and firmware against the manufacturer datasheets.

What are the typical applications for each device?

The ADS1210U is suited for precision low-frequency measurement such as industrial process control, weigh scales, and temperature sensing where PGA and multiplexing are beneficial. The ADS1252UG4 is suited for higher-speed data acquisition such as vibration monitoring and medical instrumentation where a fixed high data rate is required.