AFE5832LPZAV
STマイクロエレクトロニクス
- Lifecycle
- Active
- Stock
- 6726 個数
- Package
- NFBGA-289
- Series
- データ取得 - アナログフロントエンド (AFE)
AFE5832LPZAVとAFE5804ZCFの詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。
Replacement verdict
The AFE5832LPZAV and AFE5804ZCF are not drop-in replacements for one another. The AFE5832LPZAV is a 32-channel ultrasound analog front end in a 289-ball NFBGA package, while the AFE5804ZCF is an 8-channel ultrasound analog front end in a 100-ball NFBGA package. Their channel count, package footprint, and system-level integration differ substantially, so substituting one for the other requires board redesign and system revalidation rather than a direct swap.
STマイクロエレクトロニクス
STマイクロエレクトロニクス
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | AFE5832LPZAV | AFE5804ZCF | Why it matters |
|---|---|---|---|
| Number of Channels | 32 | 8 | Channel count determines how many transducer elements or signal paths the AFE can support; a 32-channel device serves larger arrays than an 8-channel device. |
| ADC Resolution | 12 bit | 12 bit | ADC bit depth sets the dynamic range and quantization noise floor of the receive path; both devices offer the same 12-bit resolution. |
| Maximum Sampling Rate | 80 MSPS | 50 MSPS | Higher sampling rate supports wider signal bandwidth and finer time resolution, which affects image quality and depth resolution in ultrasound systems. |
| Interface Type | LVDS (serialized JESD204B-like LVDS output) | LVDS | The digital output interface must match the downstream FPGA or receiver; differing LVDS formats affect board layout and data capture design. |
| Supply Voltage (Analog) | 1.8 V / 3.3 V (multiple rails) | 3.3 V | Supply rail requirements determine power supply design and compatibility; multi-rail devices need additional regulators and sequencing. |
| Package Type | NFBGA (ZAV) | NFBGA (ZCF) | Package footprint and pinout must match the PCB layout; different package codes indicate incompatible land patterns and pin assignments. |
| Operating Temperature Range | 0°C to 85°C | 0°C to 85°C | The temperature range defines the environments in which the device can reliably operate; both parts share the same commercial range. |
| Typical Power Consumption | ~1.1 W (low-power mode) | ~0.9 W | Power consumption affects thermal design and battery life in portable ultrasound systems; lower power reduces heat and supply demands. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | AFE5832LPZAV | AFE5804ZCF |
|---|---|---|
| Supplier | - | Rochester Electronics, LLC,Texas Instruments |
| Part Status | Active | Active |
| Number of Bits | 10, 12 | 12 |
| Number of Channels | 32 | 8 |
| Power (Watts) | - | 101 mW |
| Voltage - Supply, Analog | - | 3.15V ~ 3.47V, 5V |
| Voltage - Supply, Digital | - | 1.7V ~ 1.9V |
| Mounting Type | Surface Mount | Surface Mount |
The AFE5832LPZAV is a 32-channel, low-power analog front-end (AFE) designed for portable ultrasound systems, featuring a 12-bit ADC and integrated continuous wave (CW) Doppler processing. The AFE5804ZCF is an 8-channel AFE with a 12-bit ADC, LNA, VGA, and programmable gain amplifier, intended for general ultrasound and medical imaging applications. The AFE5832LPZAV offers higher channel density and lower power per channel, while the AFE5804ZCF provides a more compact 8-channel solution with a different power and feature profile.
No. The AFE5832LPZAV is supplied in a 289-ball NFBGA package, while the AFE5804ZCF is supplied in a 100-ball NFBGA package. The ball counts, package dimensions, and pin assignments differ, so they are not drop-in replacements and require different PCB footprints.
The AFE5832LPZAV integrates 32 receive channels with a typical power consumption of approximately 100 mW per channel, targeting low-power portable systems. The AFE5804ZCF integrates 8 receive channels with a typical power consumption of about 130 mW per channel. For a given channel count, the AFE5832LPZAV provides lower power per channel, but the total system power depends on the number of channels required.
Yes. Both the AFE5832LPZAV and the AFE5804ZCF include integrated continuous wave (CW) Doppler mixing and summing functionality, which is used in ultrasound systems for blood flow measurement. The implementation details and channel grouping may differ, so designers should consult the respective datasheets for CW performance specifications.
The AFE5832LPZAV is optimized for portable and handheld ultrasound systems where high channel count and low power are critical. The AFE5804ZCF is suited for mid-range ultrasound systems, medical imaging equipment, and applications requiring 8 channels of integrated signal conditioning with CW Doppler support. Selection depends on channel count, power budget, and system form factor.
No. Direct substitution is not possible because the two devices differ in channel count (8 vs 32), package size and ball count (100-ball vs 289-ball NFBGA), pin assignments, and power architecture. A redesign of the PCB, power supply, and digital interface would be required, and the system channel count would change significantly.
Both devices provide serialized LVDS digital output for the ADC data. The AFE5832LPZAV supports high-speed serial LVDS output suitable for 32 channels, while the AFE5804ZCF provides LVDS output for its 8 channels. The exact data rate, lane configuration, and framing should be verified in the respective manufacturer datasheets before designing the digital back-end.