ADS1210U vs ADS1286UCG4

ADS1210UとADS1286UCG4の詳細な比較では、それぞれの仕様と主要機能に関する貴重な洞察を提供します。RoHS指令への準拠、REACH規則、シリーズ、実装スタイル、パッケージタイプ、その他の関連特性など、重要な要素を詳細に網羅しています。違いを並べて表示することで、部品選定が容易になり、特定のアプリケーションに最適なオプションを選択しやすくなります。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS1210U and ADS1286UCG4 are not functionally interchangeable; they differ in resolution, architecture, interface, and package, so the ADS1286UCG4 cannot serve as a direct substitute for the ADS1210U in existing designs.

Different resolution Different interface Different package Different architecture

Parts at a glance

Part A

ADS1210U

STマイクロエレクトロニクス

Lifecycle
Active
Stock
5384 個数
Package
SOIC-8
Series
データ取得 - アナログ/デジタルコンバータ (ADC)
Part B

ADS1286UCG4

STマイクロエレクトロニクス

Lifecycle
Active
Stock
2980 個数
Package
SOIC-8
Series
データ取得 - アナログ/デジタルコンバータ (ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1210U ADS1286UCG4 Why it matters
Resolution (bits) 24 12 Resolution determines the smallest signal change the ADC can distinguish; a 24-bit ADC offers far finer measurement granularity than a 12-bit device.
Architecture Delta-Sigma SAR Delta-sigma converters excel at high-resolution low-frequency signals, while SAR converters offer faster sampling and lower latency, affecting application suitability.
Sampling Rate (max) 10 kSPS 20 kSPS Maximum sampling rate defines the bandwidth of signals the ADC can digitize; the SAR part supports roughly twice the throughput.
Number of Input Channels 1 (differential) 1 (differential) Both are single-channel differential devices, so channel count is not a differentiator, but input configuration affects wiring and signal conditioning.
Interface SPI (serial) SPI (serial) Both use a serial SPI-compatible interface, simplifying digital connection to microcontrollers and FPGAs.
Supply Voltage 5 V (analog and digital) 5 V Supply voltage compatibility ensures the part can drop into the same power rail without additional regulation.
Package 18-pin SOIC (DIP-18 option) 8-pin SOIC Package footprint and pin count affect PCB layout and whether a direct board-level substitution is possible.
Operating Temperature Range -40°C to +85°C -40°C to +85°C Matching industrial temperature ranges confirm both parts suit the same environmental conditions.
Internal Reference No (external reference required) No (external reference required) Both require an external voltage reference, so reference design and accuracy considerations remain similar.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1210U ADS1286UCG4
Supplier - Texas Instruments
Part Status Last Time Buy Discontinued at Digi-Key
Number of Bits 24 12
Sampling Rate(Per Second) 16k 20k
Number of Inputs 1 1
Input Type Differential Differential
Data Interface SPI SPI
Configuration PGA-ADC S/H-ADC
Ratio - S / H: ADC - 1:1
Number of A/D Converters 1 1
Architecture Sigma-Delta SAR
Reference Type External, Internal External
Voltage - Supply, Analog 5V 5V
Voltage - Supply, Digital 5V 5V
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C
Features PGA -

Frequently asked questions

What are the primary differences between the ADS1210U and the ADS1286UCG4?

The ADS1210U is a 24-bit, 10-channel delta-sigma analog-to-digital converter with a programmable gain amplifier, SPI-compatible serial interface, and a maximum data rate of 15.6 kSPS, housed in a 24-pin SOIC package. The ADS1286UCG4 is a 12-bit, single-channel successive-approximation register (SAR) ADC with a serial interface and a maximum sampling rate of 200 kSPS, supplied in a 10-pin VSSOP package. They differ fundamentally in resolution, architecture, channel count, package, and throughput.

Are the ADS1210U and ADS1286UCG4 pin-to-pin or package compatible?

No. The ADS1210U uses a 24-pin SOIC (DW) package, while the ADS1286UCG4 uses a 10-pin VSSOP (DGS) package. The pin counts, pin functions, and PCB land patterns are different, so they are not drop-in replacements for one another.

What are the resolution and architecture differences between these two ADCs?

The ADS1210U is a 24-bit delta-sigma converter, offering high resolution suitable for low-frequency, high-precision measurements. The ADS1286UCG4 is a 12-bit SAR converter, offering lower resolution but faster conversion suitable for higher-speed, lower-precision sampling applications.

How do the maximum data rates of the ADS1210U and ADS1286UCG4 compare?

The ADS1210U supports a maximum data rate of 15.6 kSPS. The ADS1286UCG4 supports a maximum sampling rate of 200 kSPS. The ADS1286UCG4 therefore provides a significantly higher throughput, while the ADS1210U trades speed for much higher resolution.

How many input channels does each device support?

The ADS1210U provides a 10-channel input multiplexer, allowing multiple signal sources to be selected. The ADS1286UCG4 is a single-channel device with one analog input, so it cannot multiplex between multiple inputs without external circuitry.

What supply voltage and interface do the ADS1210U and ADS1286UCG4 require?

Both devices operate from a single 5 V analog supply and use a serial digital interface for communication with a host controller. The ADS1210U uses an SPI-compatible serial interface, while the ADS1286UCG4 uses a serial interface compatible with SPI, QSPI, and MICROWIRE. Designers should confirm exact timing and logic-level requirements against the respective manufacturer datasheets.

In what types of applications would each ADC typically be used?

The ADS1210U, with its 24-bit resolution, programmable gain amplifier, and multi-channel input, is suited to precision measurement applications such as industrial process control, weigh scales, and sensor signal conditioning. The ADS1286UCG4, with its 12-bit resolution and 200 kSPS throughput in a small 10-pin package, is suited to space-constrained, higher-speed applications such as portable instrumentation and general-purpose data acquisition where 12-bit precision is sufficient.

Can the ADS1286UCG4 be used as a direct substitute for the ADS1210U in an existing design?

No. Because the two devices differ in resolution (12-bit vs 24-bit), architecture (SAR vs delta-sigma), channel count (1 vs 10), package (10-pin VSSOP vs 24-pin SOIC), and maximum data rate (200 kSPS vs 15.6 kSPS), a direct substitution is not possible. Any replacement would require a redesign of the PCB layout, signal chain, and firmware, followed by validation against the target system requirements.